MINI-SPLIT STANDARD
:42B@820:)>4285820B8=<A
*G>4
#=34: *+A ,=:B064 (0B43 # #%&
@B==: <3==@ %CB3==@ ;>A
)8<6:4/=<4
H/P LA096HNP 9,900 36V DC 115 7.2 15 20
H/P LA126HNP 11,500 36V DC 115 9.3 15 20
H/P LA096HV 9,000 230/208 230/208 3.2/3.5 8.2 15
H/P LA126HV 11,800 230/208 230/208 5.0/5.5 9.9 15
H/P LA186HV 17,600 230/208 230/208 7.3/8.0 12.4 20
H/P LA246HV 24,200 230/208 230/208 11.0/12.1 16.7 25
(45@864@0<B"8<4)>4285820B8=<A
*G>4
#=34: *+A &8>4)8H4 338B8=<0: #0F&8>4 #0F
@B==: "8?C83 )C2B8=<
(45@864@0<B
"4<6B7 :4D0B8=<
)8<6:4/=<4
H/P LA096HNP 9,900 1/4" 1/2" 0.22 oz./ft. 49' 25'
H/P LA126HNP 11,500 1/4" 1/2" 0.22 oz./ft. 49' 25'
H/P
LA096HV 9,000 1/4" 3/8" 0.22 oz./ft. 49' 25'
H/P LA126HV 11,800 1/4" 3/8" 0.22 oz./ft. 49' 25'
H/P LA186HV 17,600 1/4" 1/2" 0.22 oz./ft. 49' 25'
H/P
LA246HV 24,200 3/8" 5/8" 0.33 oz./ft. 98' 49'
#8<8;C;8@2C8B;>028BG
#0F8;C;%D4@2C@@4<B&@=B42B8=<
-8@4)8H4
Minimum wiring requirements suggested by manufacturer.
Minimum AWG 14-3
Indoor/Outdoor Connecting Cable Minimum AWG 18-4
All equipment single phase.
NOTE: Please see local electrical codes for proper
wire specifications.
LG Electronics' products have led the global air conditioner market with excellent
performance and innovative design. LSxxxHSV models, a brilliant new addition to LG's
lineup, are high-performance air conditioners with a high SEER inverter and excellent
design.
25' maximum
8' minimum
16.4' maximum
OIL TRAP
INDOOR UNIT
OUTDOOR UNIT
***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the
interior unit.
Except for LA***HV models, Systems having the outdoor unit mounted above
the indoor unit (e.g., basement installations) have the following additional
requirement: For systems with maximum elevation of 25 ft. (see chart above
and Figure A), refrigerant lines must be oil trapped between 8 ft. and 16.4 ft. of
elevation.For systems with elevation of greater than 25 ft. (see chart above),
refrigerant lines must be oil trapped at least every 16.4 ft. of elevation.
Figure A.
Example: 25 ft. maximum elevation.
#$)&"*$*
(%$*%$())$"0%$
.
Outdoor Unit
Indoor Unit