Owner's Manual

MULTI F OUTDOOR UNIT | 37
Multi F Outdoor Unit Data
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
Table 30: LMU36CHV with Mixed Indoor Units — Rated Heating Combination Table.
No. of
Indoor
Units
Indoor Unit Combination
(kBtu/h)
Room Capacity Total Capacity Input (W)
COP HSPF
IDU
1
IDU
2
IDU
3
IDU
4
Total
Unit 1
(Btu/h)
Unit 2
(Btu/h)
Unit 3
(Btu/h)
Unit 4
(Btu/h)
Minimum Rated Maximum
Min. Rated Max.
Btu/h kW Btu/h kW Btu/h kW
Mixed Indoor Units
Two
Units
7 9 - - 16 7,486 9,625 - - 10,267 3.0 17,111 5.0 18,822 5.5 1,267 1,810 2,534 2.8 7.4
9 9 - - 18 9,625 9,625 - - 11,550 3.4 19,250 5.6 21,175 6.2 1,402 2,003 2,805 2.8 7.5
7 12 - - 19 7,486 12,833 - - 12,192 3.6 20,319 6.0 22,351 6.6 1,459 2,085 2,919 2.9 7.6
9 12 - - 21 9,625 12,833 - - 13,475 3.9 22,458 6.6 24,704 7.2 1,580 2,258 3,161 2.9 7.8
9 15 - - 24 9,625 16,042 - - 15,400 4.5 25,667 7.5 28,233 8.3 1,730 2,471 3,460 3.0 8.1
12 12 - - 24 12,833 12,833 - - 15,400 4.5 25,667 7.5 28,233 8.3 1,730 2,471 3,460 3.0 8.1
7 18 - - 25 7,486 19,250 - - 16,042 4.7 26,736 7.8 29,410 8.6 1,787 2,553 3,574 3.1 8.2
9 18 - - 27 9,625 19,250 - - 17,325 5.1 28,875 8.5 31,763 9.3 1,901 2,715 3,801 3.1 8.3
12 15 - - 27 12,833 16,042 - - 17,325 5.1 28,875 8.5 31,763 9.3 1,901 2,715 3,801 3.1 8.3
12 18 - - 30 12,833 19,250 - - 19,250 5.6 32,083 9.4 35,292 10.3 2,050 2,929 4,100 3.2 8.6
7 24 - - 31 7,486 25,667 - - 19,892 5.8 33,153 9.7 36,468 10.7 2,093 2,990 4,186 3.2 8.7
9 24 - - 33 9,545 25,455 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
15 18 - - 33 15,909 19,091 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
18 18 - - 36 17,500 17,500 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
12 24 - - 36 11,667 23,333 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
15 24 - - 39 13,462 21,538 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
18 24* - - 42 15,000 20,000 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286 3.4 9.0
24 24* - - 48 17,500 17,500 - - 21,000 6.2 35,000 10.3 38,500 11.3 2,143 3,061 4,286
3.4 9.0
Three
Units
7 7 9 - 23 7,486 7,486 9,625 - 14,758 4.3 24,597 7.2 28,287 8.3 1,644 2,349 3,289 3.1 8.2
7 9 9 - 25 7,486 9,625 9,625 - 16,042 4.7 26,736 7.8 30,747 9.0 1,758 2,512 3,517 3.1 8.3
7 7 12 - 26 7,486 7,486 12,833 - 16,683 4.9 27,806 8.1 31,976 9.4 1,787 2,553 3,574 3.2 8.5
9 9 9 - 27 9,625 9,625 9,625 - 17,325 5.1 28,875 8.5 33,206 9.7 1,815 2,593 3,631 3.3 8.7
7 9 12 - 28 7,486 9,625 12,833 - 17,967 5.3 29,944 8.8 34,436 10.1 1,851 2,644 3,702 3.3 8.9
9 9 12 - 30 9,625 9,625 12,833 - 19,250 5.6 32,083 9.4 36,896 10.8 1,929 2,756 3,858 3.4 9.1
7 9 15 - 31 7,486 9,625 16,042 - 19,892 5.8 33,153 9.7 38,126 11.2 1,972 2,817 3,944 3.4 9.2
7 12 12 - 31 7,486 12,833 12,833 - 19,892 5.8 33,153 9.7 38,126 11.2 1,972 2,817 3,944 3.4 9.2
7 7 18 - 32 7,486 7,486 19,250 - 20,533 6.0 34,222 10.0 39,356 11.5 2,015 2,878 4,029 3.5 9.3
9 9 15 - 33 9,545 9,545 15,909 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 12 12 - 33 9,545 12,727 12,727 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 9 18 - 34 7,206 9,265 18,529 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 12 15 - 34 7,206 12,353 15,441 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 9 18 - 36 8,750 8,750 17,500 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 12 15 - 36 8,750 11,667 14,583 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
12 12 12 - 36 11,667 11,667 11,667 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 12 18 - 37 6,622 11,351 17,027 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 7 24 - 38 6,447 6,447 22,105 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 12 18 - 39 8,077 10,769 16,154 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 15 15 - 39 8,077 13,462 13,462 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015
2,878 4,029 3.6 9.5
12 12 15 - 39 10,769 10,769 13,462 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 9 24 - 40 6,125 7,875 21,000 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 15 18 - 40 6,125 13,125 15,750 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 9 24* - 42 7,500 7,500 20,000 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 15 18 - 42 7,500 12,500 15,000 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
12 12 18 - 42 10,000 10,000 15,000 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
12 15 15 - 42 10,000 12,500 12,500 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 12 24* - 43 5,698 9,767 19,535 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
7 18 18 - 43 5,698 14,651 14,651 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
9 12 24* - 45 7,000 9,333 18,667 - 21,000 6.2 35,000 10.3 40,250 11.8 2,015 2,878 4,029 3.6 9.5
Rated Heating Combination Tables
PERFORMANCE DATA
1
Capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
2
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
3
Wiring cable size must comply with the applicable local and national codes.
4
The specification may be subject to change without prior notice for purpose of improvement.
5
At least two indoor units should be connected.
*The multiplier (1.3) is necessary for the calculation of total combination.