76 | STD. WALL-MOUNTED
Multi F and Multi F MAX Indoor Unit Engineering Manual
MULTI
F
MAX
MULTI
F
,QVWDOODWLRQDQG%HVW/D\RXW3UDFWLFHV
Power Wiring / Communications Cable Guidelines
STANDARD WALL-MOUNTED INDOOR UNITS
Follow manufacturer’s circuit diagrams in the technical manuals.
Confirm power source specifications.
Confirm that the electrical capacity is sufficient.
Starting current must be maintained ±10 percent of the rated current marked on the outdoor unit name plate.
Confirm cable thickness specifications.
It is recommended that a circuit breaker is installed, especially if conditions could become wet or moist.
Include a disconnect in the power wiring system, add an air gap contact separation of at least 1/8 inch in each active (phase) conductor.
Terminal block
Power wiring /
communications cable
Wired Remote Controlle
r
Terminal (Optional)
Cable restraint
Figure 101: Connecting Power Wiring / Communications Cable.
Connect Power Wiring and
Communications Cable
1. Insert the power wiring / communications cable from the outdoor
unit or branch distribution unit (Multi F MAX systems only) through
the bottom of the indoor unit.
2. Connect each wire to its appropriate terminal on the indoor unit
control board. Verify that the color and terminal numbers from the
outdoor unit or branch distribution unit (Multi F MAX systems only)
wiring match the color and terminal numbers on the indoor unit.
3. Secure power wiring/communications cable with cable restraint.
Figure 102: 6LPSOL¿HG9LHZRI,QGRRU8QLWWR2XWGRRU8QLW%UDQFK
Distribution Unit Terminal Connections—LMN078HVT, LSN090HSV4,
LSN120HSV4 and LMN158HVT.
Figure 103: 6LPSOL¿HG9LHZRI,QGRRU8QLWWR2XWGRRU8QLW%UDQFK
Distribution Unit Terminal Connections— LSN180HSV4 and
LMN248HVT.
Indoor Unit Terminal Block
GND
Outdoor Unit Terminal Block or
Branch Distribution Unit Terminal Block
(Multi F MAX Systems Only)
GND
GRN / YLW
BR
BL
RD
3 or S
32(L2)1(L1)
Indoor Unit Terminal Block
1(L1) 2(L2)
GND
Outdoor Unit Terminal Block or
Branch Distribution Unit Terminal Block
(Multi F MAX Systems Only)
GND
GRN / YLW
BR
BL
RD
3
3 or S
/RRVHZLULQJPD\FDXVHXQLWWRPDOIXQFWLRQRYHUKHDWDQGFDWFK
ILUHUHVXOWLQJLQVHYHUHLQMXU\RUGHDWK
Note:
Terminal screws may become loose during transport. Properly
tighten the terminal connections during installation.
$YROWDJHGURSPD\FDXVHWKHIROORZLQJSUREOHPV
0DJQHWLF VZLWFK YLEUDWLRQ IXVH EUHDNV RU GLVWXUEDQFH WR WKH
normal function of an overload protection device.
Compressor will not receive the proper starting current.