1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.
2. Rated cooling capacity obtained with air entering the indoor unit at 80˚F dry bulb (DB) and 67˚F wet bulb (WB) and outdoor ambient conditions of 95˚F dry bulb (DB) and 75˚F wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70˚F dry bulb (DB) and 60˚F wet bulb (WB) and outdoor ambient conditions of 47˚F dry bulb (DB) and 43˚F wet bulb (WB).
For capacity information, see engineering manual capacity tables.
3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.
4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to 0˚F in cooling mode for applicable outdoor units.
5. Airflow shown is in cooling mode.
6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.
7. Piping lengths are equivalent.
8. Due to our commitment to continued innovation, some specifications may be changed without notification.
SINGLE ZONE
ART COOL
™
PREMIER with LGRED° heat
LA090HYV1
LA120HYV1
LA150HYV2
LA180HYV2
Specification Unit LA090HYV1 LA120HYV1 LA150HYV2 LA180HYV2
Indoor Unit LAN090HYV1 LAN120HYV1 LAN150HYV2 LAN180HYV2
Outdoor Unit LAU090HYV1 LAU120HYV1 LAU150HYV2 LAU180HYV2
Rated Cooling Capacity
Btu/h
9,000 11,000 15,000 18,200
Cooling Capacity Range Btu/h
1,023 ~ 12,966 1,023 ~ 13,785 3,070 ~ 21,000 3,070 ~ 29,515
Rated Heating Capacity Btu/h
11,000 12,000 18,000 22,000
Heating Capacity Range Btu/h
1,023 ~ 20,472 1,023 ~ 22,178 3,070 ~ 25,200 3,070 ~ 32,000
Capacity
Max Heating Capacity at 17°F Btu/h
11,940 14,650 21,430 27,400
Max Heating Capacity at 5°F Btu/h
11,220 13,720 18,950 24,360
Max Heating Capacity at -13°F Btu/h
7,920 9,520 14,660 19,120
SEER, EER
27.5, 15.65 25.5, 13.75 24.0, 13.48 22.0, 12.5
HSPF
12 12 12.5 12.0
Power
Voltage (IDU) V, Ø, Hz
208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Voltage (ODU) V, Ø, Hz
208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Cooling Power Input kW
0.58 0.8 1.11 1.46
Heating Power Input kW
0.71 0.75 1.39 1.79
MCA, MOCP A
11.2, 15 11.2, 15 19.0, 25 19.0, 25
Power/Communication Wiring
4
No. x AWG
4 x 14 4 x 14 4 x 14 4 x 14
Rated Amps Cool/Heat A
8.7/8.7 8.7/8.7 15.0/15.0 15.0/15.0
Operating Range
Heating Operation Range °F WB
-13 ~ 65 -13 ~ 65 -13~65 -13~65
Cooling Operation Range °F DB
14~118 14~118 14~118 14~118
Optional Wind Bafe
6
ZLABGP01A (0˚F) ZLABGP01A (0˚F) ZLABGP02A (0˚F) ZLABGP02A (0˚F)
IDU Operation Range Cooling °F WB
53 ~ 75 53 ~ 75 53 ~ 75 53 ~ 75
IDU Operation Range Heating °F DB
60 ~ 86 60 ~ 86 60 ~ 86 60 ~ 86
Setpoint Range Cooling °F
64 ~ 86 64 ~ 86 64 ~ 86 64 ~ 86
Setpoint Range Heating °F
60 ~ 86 60 ~ 86 60 ~ 86 60 ~ 86
Dimensions
IDU Dimensions (WxHxD) in
34-7/16x11-5/8x9-1/4 34-7/16x11-5/8x9-1/4 42-15/16x12-31/32x9-25/32 42-15/16x12-31/32x9-25/32
ODU Dimensions (WxHxD) in
30-5/16x21-1/2x11-5/16 30-5/16x21-1/2x11-5/16 34-1/4 x 31-1/2 x 12-19/32 34-1/4 x 31-1/2 x 12-19/32
Weight
IDU Weight (Net/Shipping) lbs
24/30 24/30 34/38 34/38
ODU Weight (Net/Shipping) lbs
77/82 77/82 122/131 122/131
Unit Data
Airow (Max/H/M/L) CFM
547/494/417/283 547/494/417/283 742/565/424/318 777/565/424/318
Dehumidification pts/hr
3.20 3.60 3.80 4.60
Compressor Type
Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Refrigerant Type
R410A R410A R410A R410A
Sound Pressure
Indoor (H/M/L/SL) dB(A)
42/36/25/17 42/36/25/17 47/42/37/29 47/42/37/29
Outdoor Max dB(A)
45 45 57 57
Piping
Liquid Pipe in
1/4 1/4 3/8 3/8
Vapor Pipe in
3/8 3/8 5/8 5/8
Pipe Length (Min/Max) ft
6.6/65.6 6.6/65.6 9.8/98.4 9.8/98.4
Max Pipe Elevation ft
32.8 32.8 65.6 65.6
Precharge Pipe Length ft
41 41 24.6 24.6
Additional Refrigerant oz/ft
0.22 0.22 0.38 0.38
Drain (OD, ID) in
27/32, 5/8 27/32, 5/8 27/32, 5/8 27/32, 5/8
Controller Supplied