Brochure

13
LG Air Conditioning Technologies
ART COOL
PREMIER
LA180HYV1
LA240HYV1
Specification Unit LA180HYV1 LA240HYV1
Indoor Unit LAN180HYV1 LAN240HYV1
Outdoor Unit LAU180HYV1 LAU240 HYV1
Capacity
Rated Cooling Capacity
Btu/h
18,200 22,000
Cooling Capacity Range Btu/h
3,070 ~ 29,515 3,070 ~ 30,000
Rated Heating Capacity Btu/h
22,000 27,000
Heating Capacity Range Btu/h
3,070 ~ 30,709 3,070 ~ 35,200
Max Heating Capacity at 17°F Btu/h
22,340 27,410
Max Heating Capacity at 5°F Btu/h
19,300 23,690
Max Heating Capacity at -13°F Btu/h
14,060 17,250
SEER, EER
24, 13.48 22, 12.5
HSPF
13 12.3
Power
Voltage (IDU) V, Ø, Hz
208-230, 1, 60 208-230, 1, 60
Voltage (ODU) V, Ø, Hz
208-230, 1, 60 208-230, 1, 60
Cooling Power Input kW
1.35 1.76
Heating Power Input kW
1.69 2.19
MCA, MOCP A
19, 25 19, 25
Power/Communication Wiring
3
No. x AWG
4 x 14 4 x 14
Rated Amps Cool/Heat A
15.3/15.3 15.3/15.3
Operating Range
Heating Operation Range °F WB
-13 ~ 65 -13 ~ 65
Cooling Operation Range °F DB
14 ~ 118 14 ~ 118
Optional Wind Bafe
4
ZLABGP02A (0˚F) ZLABGP02A (0˚F)
IDU Operation Range Cooling °F WB
53 ~ 75 53 ~ 75
IDU Operation Range Heating °F DB
60 ~ 86 60 ~ 86
Setpoint Range Cooling °F
64 ~ 86 64 ~ 86
Setpoint Range Heating °F
60 ~ 86 60 ~ 86
Dimensions
IDU Dimensions (WxHxD) in
42-15/16 x 12-31/32 x 9-25/32 42-15/16 x 12-31/32 x 9-25/32
ODU Dimensions (WxHxD) in
34-1/4 × 31-1/2 × 12-19/32 34-1/4 × 31-1/2 × 12-19/32
Weight
IDU Weight (Net/Shipping) lbs
34/38 34/38
ODU Weight (Net/Shipping) lbs
122/131 122/131
Unit Data
Airflow (Max/H/M/L) CFM
742/565/424/318 777/565/424/318
Dehumidification pts/hr
3.80 4.70
Compressor Type
Twin Rotary Twin Rotary
Refrigerant Type
R-410A R-410A
Sound Pressure
Indoor (H/M/L/SL) dB(A)
47/42/37/29 47/42/37/29
Outdoor Max dB(A)
57 57
Piping
Liquid Pipe in
3/8 3/8
Vapor Pipe in
5/8 5/8
Pipe Length (Min/Max) ft
9.8/98.4 9.8/98.4
Max Pipe Elevation ft
65.6 65.6
Precharge Pipe Length ft
24.6 24.6
Additional Refrigerant oz/ft
0.38 0.38
Drain (OD, ID) in
27/32, 5/8 27/32, 5/8
Controller Supplied
AKB74835304 AKB74835304
Note:
1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.
2. Rated cooling capacity obtained with air entering the indoor unit at 80˚F dry bulb (DB) and 67˚F wet bulb (WB) and outdoor ambient conditions of 95˚F dry bulb (DB) and 75˚F wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70˚F dry bulb (DB) and 60˚F wet bulb (WB) and outdoor ambient conditions of 47˚F dry bulb (DB) and 43˚F wet bulb (WB).
For capacity information, see engineering manual capacity tables.
3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.
4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to 0˚F in cooling mode for applicable outdoor units.
5. Airflow shown is in cooling mode.
6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.
7. Piping lengths are equivalent.
8. Due to our commitment to continued innovation, some specifications may be changed without notification.