Brochure

26
Specication Unit LMU360HHV LMU420HHV
Capacity
Rated Cooling Capacity Btu/h
36,000 42,000
Cooling Capacity Range Btu/h
11,700 ~ 46,733 11,700 ~ 53,897
Rated Heating Capacity Btu/h
41,000 45,000
Heating Capacity Range Btu/h
13,455 ~ 50,200 13,455 ~ 55,256
Max Heating Capacity at 17°F Btu/h
45,510 49,950
Max Heating Capacity at 5°F Btu/h
41,000 45,000
Max Heating Capacity at -4°F Btu/h
36,900 39,150
Max Heating Capacity at -13°F Btu/h
32,390 34,200
SEER, EER
3
21, 15 20.5, 14
HSPF
3
11.5 11
Power
Voltage V- Ø - Hz
208/230-1-60 208/230-1-60
Cooling Power Input kW
2.4 3
Heating Power Input kW
2.93 3.3
MCA, MOCP
4
A
30.2, 45 30.2, 45
Rated Amps A
25.06 25.06
Power/Communication Wiring
5
A
ODU --> BDU: 4 x 14
BDU --> IDU: 4 x 14
ODU --> BDU: 4 x 14
BDU --> IDU: 4 x 14
Operating Range
Heating Operation Range °F WB
-13 - 64 -13 - 64
Cooling Operation Range °F DB
14 - 118 14 - 118
Optional Wind Bafe
6
ZLABGP04A x2 (-4˚F) ZLABGP04A x2 (-4˚F)
Dimensions & Weight
Dimensions (WxHxD) in
37-13/32 x 54-11/32 x 13 37-13/32 x 54-11/32 x 13
Weight (Net/Shipping) lbs
222.7/249.1 222.7/249.1
Unit Data
Refrigerant Type R410A R410A
Compressor Type Twin Rotary Twin Rotary
Sound Pressure (Cooling / Heating)
7
dB(A) 54 / 57 54 / 57
Maximum Air Volume CFM 2,119 x 2 2,119 x 2
Minimum Connectable IDUs Qty 2 2
Maximum Connectable IDUs Qty 5 6
Max Total IDU Connected Capacity Btu/h 48,000 56,000
Piping
Liquid Pipe in 3/8 3/8
Vapor Pipe in 3/4 3/4
Maximum Total Pipe Length ft 475.7 475.7
Minimum Pipe Length per Segment ft 9.8 9.8
Maximum Pipe Length ODU to IDU ft 229.6 229.6
Maximum Main Pipe Length (ODU to BDU) ft 180.4 180.4
Maximum Branch Piping ft 295.3 295.3
Maximum Pipe Length BDU to IDU ft 49.2 49.2
Precharge Pipe Length ft
Main: 16.4
Branch: 131.2
Main: 16.4
Branch: 131.2
Maximum Elevation ODU to IDU ft 98.4 98.4
Maximum Elevation IDU to IDU ft 49.2 49.2
Maximum Elevation BDU to IDU ft 32.8 32.8
Maximum Elevation BDU to BDU ft 49.2 49.2
Factory Charge of R410A lbs 12.3 12.3
Additional Refrigerant oz/ft
Main: 0.54
Branch: 0.22
Main: 0.54
Branch: 0.22
Multi-Zone
Multi-Zone
OUTDOOR UNITS
MULTI F MAX OUTDOOR UNITS with LGRED°
LMU360HHV
LMU420HHV
Note:
1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.
2. Rated cooling capacity obtained with air entering the indoor unit at 80˚F dry bulb (DB) and 67˚F wet bulb (WB) and outdoor ambient conditions of 95˚F dry bulb (DB) and 75˚F wet bulb (WB). Rated heating
capacity obtained with air entering the indoor unit at 70˚F dry bulb (DB) and 60˚F wet bulb (WB) and outdoor ambient conditions of 47˚F dry bulb (DB) and 43˚F wet bulb (WB). For capacity information, see
engineering manual capacity tables. Capacities are based on connection of Non-Ducted indoor units.
3. Values when matched with non-ducted units only.
4. Recommended fuse sze is 25 Amps.
5. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.
6. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -4˚F in cooling mode for applicable outdoor units.
7. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.
8. Piping lengths are equivalent.
9. Due to our commitment to continued innovation, some specifications may be changed without notification.