- Open the control box cover and connect the
remote controller cables, transmission
cables and indoor power cables.
- Control box cover is consist of two panel
which are side and bottom panel.
Control box cover can be separated
from main body by 2 method.
Case 1. Separate whole cover(when access
from bottom of the product).
Remove screws on the bottom panel
and grab the both panel with two
hands and pull down the whole cover.
Case 2. Separate only side panel(when access
from side of the product).
Remove screws which are connecting
two panel and pull down the side
panel.
Side panel