HOW TO SET E.S.P?
ENGLISH
Capacity
Step
CFM
Static Pressure(mmAq(in.Aq))
2.5(0.1) 4(0.15) 6(0.23) 8(0.31) 10(0.39) 12(0.47) 14(0.55) 16(0.62) 18(0.70) 20(0.78)
Setting Value
24 k
HIGH 688 82 92 103 113 122 131 140 147 154 160
MID 618 78 89 99 110 119 128 137 144 151 157
LOW 530 73 86 96 107 116 125 134 141 148 154
36 k
HIGH 1 130 - 124 133 140 148 154 160 - - -
MID 953 - 112 122 130 137 155 152 - - -
LOW 706 - 97 107 117 125 133 141 - - -
Capacity
Step
CFM
Static Pressure(mmAq(in.Aq))
2.5(0.1) 4(0.15) 6(0.23) 8(0.31) 10(0.39) 12(0.47) 14(0.55) 15(0.6) 16(0.62) 18(0.70) 20(0.78)
Setting Value
24 k
HIGH 688 90 97 108 119 126 134 143 146 149 157 159
MID 618 86 93 105 115 123 131 140 143 146 153 156
LOW 530 82 90 102 112 120 128 137 140 143 150 153
36 k
HIGH 1 130 - 96 103 109 115 120 126 129 - - -
MID 953 - 85 96 102 109 115 121 124 - - -
LOW 706 - 76 85 95 100 107 113 116 - - -
<TYPE B>
<TYPE C>
Capacity
Step CFM
Static Pressure(mmAq(in.Aq))
2.5(0.1) 4(0.16) 5(0.2) 6(0.24) 7(0.28) 8(0.31) 9(0.35) 10(0.39) 11(0.43) 12(0.47) 13(0.51) 15(0.59)
Setting Value
24 k
HIGH 777 110 117 121 124 127 130 133 136 137 - 138 140
MID 706 102 110 114 118 120 125 127 130 133 - 134 136
LOW 636 96 102 107 110 114 118 122 125 127 - 130 132
36 k
HIGH 1 130 - 109 112 115 119 122 126 128 131 134 137 144
MID 989 - 101 105 108 112 115 119 123 127 130 133 138
LOW 848 - 92 97 101 105 109 113 117 121 124 127 134