ENGLISH FRANÇAIS ESPAÑOL OWNER’S & INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly. This manual is the simplified version of original manual. You can obtain the original manual from website. MFL71420009 Rev.09_070723 www.lghvac.com www.
INSTALLATION MANUAL ENGLISH MODEL DESIGNATION Airborne Noise Emission The A-weighted sound pressure emitted by this product is below 70 dB. ** The noise level can vary depending on the site. The figures quoted are emission level and are not necessarily safe working levels. Whilst there is a correlation between the emission and exposure levels, this cannot be used reliably to determine whether or not further precautions are required.
SAFETY INSTRUCTIONS The following safety guidelines are intended to prevent unforeseen risks or damage from unsafe or incorrect operation of the appliance. The guidelines are separated into ‘WARNING’ and ‘CAUTION’ as described below. ! ! This symbol is displayed to indicate matters and operations that can cause risk. Read the part with this symbol carefully and follow the instructions in order to avoid risk.
SAFETY INSTRUCTIONS ENGLISH Operation • When the product is soaked (flooded or submerged) in water , contact an Authorized Service Center for repair before using it again. There is risk of fire or electric shock. • Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment. The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire. • Do not touch, operate, or repair the product with wet hands.
SAFETY INSTRUCTIONS • Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture. • Do not expose your skin or kids or plants to the cool or hot air draft. This could harm to your health. • Do not drink the water drained from the product. It is not sanitary and could cause serious health issues. • Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
INSTALLATION MANUAL - There should not be any heat source or steam near the unit. - There should not be any obstacles to prevent the air circulation. - A place where air circulation in the room will be good. - A place where drainage can be easily obtained. - A place where noise prevention is taken into consideration. - Do not install the unit near the door way. - Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles. - The indoor unit must keep the maintenance space.
INSTALLATION MANUAL More than 13-25/32” (350) Wiring Connection Connect the wires to the terminals on the control board individually according to the outdoor unit connection. Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively. L1 More than 23-5/8” (600) clearance from access panels for Service L2 3 Connected to outdoor unit or B.D. unit.
OWNER'S MANUAL ENGLISH MAINTENANCE When the air conditioner is not going.... Clean the product regularly to maintain optimal performance and to prevent possible breakdown. When air conditioner is not going to be used for a long time. 1 Operate the air conditioner at the following settings for 2 to 3 hours. • Type of operation: Fan operation mode.(Refer to page "Fan Mode") • This will dry out the internal mechanisms.
OWNER'S MANUAL Check the following points before requesting repairs or service.... If the malfunction persist, please contact your dealer. Case Explanation The air conditioner does not operate. • Have you made a mistake in timer operation? • Has the fuse blown or has the circuit breaker been tripped? The room has a peculiar odor. • Check that this is not a damp smell exuded by the walls, carpet, furniture or cloth items in the room. It seems that condensation is leaking from the air conditioner.
LIMITED WARRANTY (USA) ENGLISH LIMITED WARRANTY (USA) The product’s full Limited Warranty terms and conditions and arbitration requirements are available at https://www.lghvac.
WARRANTY (CANADA) 11 ARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION THAT REQUIRES YOU AND LG TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF IN COURT, UNLESS THE LAWS OF YOUR PROVINCE OR TERRITORY DO NOT PERMIT THAT, OR, IN OTHER JURISDICTIONS, IF YOU CHOOSE TO OPT OUT. IN ARBITRATION, CLASS ACTIONS AND JURY TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TITLED “PROCEDURE FOR RESOLVING DISPUTES” BELOW.
WARRANTY (CANADA) ENGLISH Arbitration Rules and Procedures. To begin arbitration of a claim, either you or LG must make a written demand for arbitration. The arbitration will be private and confidential, and conducted on a simplified and expedited basis before a single arbitrator chosen by the parties under the provincial or territorial commercial arbitration law and rules of the province or territory of your residence.
WARRANTY (CANADA) 13 In the event that you “Opt Out”, the law of the province or territory of your residence shall govern this Limited Warranty and any disputes between you and LG except to the extent that such law is preempted by or inconsistent with applicable federal or provincial/territorial law.
ENGLISH
* The following mark and paragraph should be applicable only to the Energy Star certification models. IMPORTANT - This product has been designed and manufactured to meet ENERGY STAR criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant charging and air flow instructions.