Installation Manual

STEP 3: Prepare The Venting Blower
ROOF-VENTED INSTALLATION:
1. Remove one blower unit mounting screw and
one or several blower plate mounting screw(s).
Remove the blower plate from cabinet. See
Figure 19.
2. Carefully lift the blower unit out of the microwave
oven.
3. Rotate blower unit 90 so the exhaust ports face
the top of the cabinet. See Figure 20.
4. Place blower unit back into microwave oven.
5. Use side cutter or tin snips to cut and remove knockouts
"A" from blower plate. Discard knockouts. Be careful not
to distort the plate. See Figure 21.
6. Reattach blower plate to microwave oven.
Attach with the one blower unit mounting screw and then
the one or several blower plate mounting screw(s).
See Figure 22.
Figure 19
Figure 20
Blower Unit
90°
blower plate
mounting
screws
blower unit
mounting screw
blower plate
blower plate
Knockouts "A"
Figure 21
˚
blower unit
mounting screws
blower unit
blower plate
blower plate
mounting
screws
7. Insert the tabs on each side of the damper into the holes
at the inside rear of the adaptor.
Attach the exhaust adaptor to the blower plate with the two
tapping screws provided. See Figure 23.
Make sure that the damper swings freely.
Figure 22
11
Figure 23
Damper
Back of
Oven
Exhaust
Adaptor
Blower Plate