Engineering Data Guide

80 Accessories
Controller accessories 6RWU0-02A
PTAC
For 265 Volt Installation
1) At First, remove and discard the red lead of the Hard wire
assembly.
2) Connect the Black lead of the Hard wire assembly to one
terminal of the disconnect switch as shown in the figure
on the right.
3) Remove the knockout from the desired power entry point
of the junction box and route the field supply power wires
into the junction box.
4) Connect the black lead of the power supply to the remain-
ing disconnect switch terminals.
5) Connect the ground wire of the field power supply to the
bare ground wire assembly.
6) Connect the white lead of the wire assembly to the
Neutral lead of the power supply.
7) Mount the switch on the tabs in the junction box and
install the switch cover plate provided with the power
switch as shown in the figure on the right.
Fig: 265V Power Switch