9) Install Tube #1 and Tube # 2 of the pump assembly using
Rubber elbows as show in the figure on the right.
10) Position the pump assembly onto the base pan into the
slots provided adjacent to the compressor, by means of
the three screws as shown below.
11) Insert Tube # 2 of the pump assembly through the plas-
tic grommet of the sheet metal partition between the
indoor and the outdoor side of the PTAC. And then con-
nect the end of the Tube # 2 to the plastic elbow coming
out of the inlet of the spraying tube as shown on the
right.
Tube # 2
Tube #2
Tube #1
Tube # 1
Fig:Position of the condensate pump adjacent to com-
pressor
Fig:Connection between Tube # 2 and the spray tube