Engineering Data Guide

Product Data 49
PTAC
6RWU0-02A YA Chassis
Heating Capacity
DB°F TC PI TC PI TC PI TC PI TC PI TC PI
60.8 1.22 0.45 1.44 0.47 1.63 0.52 1.95 0.56 2.14 0.59 2.42 0.63
64.4 1.23 0.46 1.45 0.49 1.63 0.53 1.93 0.58 2.09 0.60 2.42 0.64
68.0 1.23 0.48 1.45 0.51 1.62 0.55 1.90 0.59 2.07 0.61 2.43 0.65
69.8 1.23 0.48 1.45 0.52 1.62 0.56 1.88 0.60 2.07 0.62 2.40 0.65
71.6 1.22 0.49 1.45 0.52 1.61 0.57 1.86 0.60 2.08 0.62 2.37 0.66
75.2 1.20 0.51 1.41 0.54 1.58 0.58 1.83 0.61 2.09 0.63 2.33 0.66
Outdoor Air Temperature : WB°F
14 23 32 42.8 50 59
Indoor Air
Temperature
AYH073ALE20(LP073HD2A), AYH073ALE30(LP073HD3A)
DB°F TC PI TC PI TC PI TC PI TC PI TC PI
60.8 1.76 0.63 1.98 0.65 2.17 0.70 2.49 0.74 2.68 0.77 2.96 0.81
64.4 1.77 0.64 1.99 0.67 2.17 0.71 2.47 0.76 2.63 0.78 2.96 0.82
68.0 1.77 0.66 1.99 0.69 2.16 0.73 2.44 0.77 2.61 0.79 2.97 0.83
69.8 1.77 0.66 1.99 0.70 2.16 0.74 2.42 0.78 2.61 0.80 2.94 0.83
71.6 1.76 0.67 1.99 0.70 2.15 0.75 2.40 0.78 2.62 0.80 2.91 0.84
75.2 1.74 0.69 1.95 0.72 2.12 0.76 2.37 0.79 2.63 0.81 2.87 0.84
Outdoor Air Temperature : WB°F
14 23 32 42.8 50 59
Indoor Air
Temperature
AYH093ALE30(LP093HD3A)
DB°F TC PI TC PI TC PI TC PI TC PI TC PI
60.8 2.48 0.82 2.70 0.84 2.89 0.89 3.21 0.93 3.40 0.96 3.68 1.00
64.4 2.49 0.83 2.71 0.86 2.89 0.90 3.19 0.95 3.35 0.97 3.68 1.01
68.0 2.49 0.85 2.71 0.88 2.88 0.92 3.16 0.96 3.33 0.98 3.69 1.02
69.8 2.49 0.85 2.71 0.89 2.88 0.93 3.14 0.97 3.33 0.99 3.66 1.02
71.6 2.48 0.86 2.71 0.89 2.87 0.94 3.12 0.97 3.34 0.99 3.63 1.03
75.2 2.46 0.88 2.67 0.91 2.84 0.95 3.09 0.98 3.35 1.00 3.59 1.03
Outdoor Air Temperature : WB°F
14 23 32 42.8 50 59
Indoor Air
Temperature
AYH123ALE30(LP123HD3A)
DB°F TC PI TC PI TC PI TC PI TC PI TC PI
60.8 2.88 1.21 3.10 1.23 3.29 1.28 3.61 1.32 3.80 1.35 4.08 1.39
64.4 2.89 1.22 3.11 1.25 3.29 1.29 3.59 1.34 3.75 1.36 4.08 1.40
68.0 2.89 1.24 3.11 1.27 3.28 1.31 3.56 1.35 3.73 1.37 4.09 1.41
69.8 2.89 1.24 3.11 1.28 3.28 1.32 3.54 1.36 3.73 1.38 4.06 1.41
71.6 2.88 1.25 3.11 1.28 3.27 1.33 3.52 1.36 3.74 1.38 4.03 1.42
75.2 2.86 1.27 3.07 1.30 3.24 1.34 3.49 1.37 3.75 1.39 3.99 1.42
Outdoor Air Temperature : WB°F
14 23 32 42.8 50 59
Indoor Air
Temperature
AYH153ALE30(LP153HD3A), AYH153ALE50(LP153HD5A)
Symbol Notes
DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.
WB : Wet Bulb Temperature [°F] 2. Indicates nominal maximum capacity.
TC : Total Capacity [kW]
PI : Power Input [kW]
(Comp.+ indoor fan motor + outdoor fan motor)