Brochure
Warranty: 2 years parts; 5 years compressor.
See page 17 for installation materials.
FLEX MULTI-SPLIT
-/"?
Energy Saving
with LG inverter Technology
Wide Choice of Indoor Units
Standard, Art Cool, Concealed Duct,
Cassette Types
Design Flexibility
Outdoor units connect to several indoor unit styles
DUAL-ZONE
LMU185HV
TRI-ZONE
LMU245HV
QUAD-ZONE
LMU365HV
OUTDOOR UNITS H/P INVERTER
18,000-36,000 BTUs
LMU185HV
Dual-Zone
LMU245HV
Tri-Zone
LMU365HV
Quad-Zone
• Defrost /Deicing
•
Restart delay (3-minutes)
• Self diagnosis
• Soft start
• Auto operation (Artificial
i
ntelligence)
• Auto restart operation
• Low ambient operation
• Gold Fin™ Anti-Corrosion
Exterior Unit Includes:
• Exterior unit
• Sufficient refrigerant for
charging 2, 3 or 4 indoor coils
(Please see chart below for
actual length amount included)
*+()
DUAL-ZONE
LMU185HV
Outdoor Units H/P Inverter
TRI-ZONE
LMU245HV
QUAD-ZONE
LMU365HV
Outdoor Model H/P Inverter # LMU185HV LMU245HV LMU365HV
Capacity * — BTU/h 18,000 Class 24,000 Class 36,000 Class
Power Input
(Min.~Rated~Max.) Cooling kW 0.52~1.26~2.05 0.72~1.64~3.27 0.72~3.21~3.92
Heating kW 0.77~1.63~2.18 0.72~2.86~3.5 0.72~3.7~4.10
Running Current Cooling A 2.3~5.7~9.5 3.0~7.2~14.5 3.0~14.2~17.3
Heating A 3.4~7.2~9.6 4.5~12.4~15.5 4.5~16.3~18.5
Power Supply — Ø / V / Hz 1/208~230/60 1/208~230/60 1/208~230/60
Power Supply Cable (Outdoor) — No. x AWG 3 x 14 3 x 12 3 x 12
Transmission Cable —
(Outdoor to Indoor unit )
No. x AWG 4 x 18 4 x 18 4 x 18
Dimensions (W x H x D) inch 34.3x25.8x12.6 34.3x31.8x12.6 34.3x31.8x12.6
Net Weight — lbs 115 143.3 143.3
Max. # of Connectable
Indoor Units
——234
Refrigerant Charge (at 24.6 ft.) oz 59.97 89.95 89.95
Type — R410A R410A R410A
Control — EEV EEV EEV
Sound Level (H/L) Sound Pressure dB(A)+3 51/45 52 52
Piping Connections Liquid inch 1/4 x 2EA 1/4 x 3EA 1/4 x 4EA
Gas inch 3/8 x 2EA 3/8 x 3EA 3/8 x 4EA
Piping length spec. Max. total piping ft. 164.0 246.1 246.1
Max. OD~ID piping ft. 82.0 82.0 82.0
Piping length(no add’l refrigerant) ft. 73.8 123.0 123.0
Max. Elevation Difference Outdoor Unit~Indoor Unit ft. 49.2 49.2 49.2
Indoor Unit~Indoor Unit ft. 24.6 24.6 24.6
Operation Range Cooling ˚F 14 ~114.8 14 ~114.8 14 ~114.8
(Outdoor) Heating ˚F 5~ 75.2 5~ 75.2 5~ 75.2
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 80ºF (26.7ºC ) DB/67ºF (19.4ºC) WB
- Outdoor Temperature 95ºF (35ºC) DB/75ºF (23.9ºC) WB
Heating: - Indoor Temperature 70ºF (21.1ºC) DB/60ºF (15.6ºC) WB
- Outdoor Temperature 47ºF (8.3ºC) DB/43ºF (6.1ºC) WB
Piping Length: - Interconnecting Piping Length 24.6 ft.(7.5m)
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of
improvement.
4. For more capacity(*) information, refer to the combination tables.
5. The data mentioned in the above table are only for non-ducted type of indoor unit.
• Installation manual
ETL# : 3091879