Owner's Manual
Table Of Contents
21INSTALLATION
ENGLISH
Water Pressure
You will need a cold water supply.
If the water pressure from the reverse osmosis 
system is less than 20 psi or 138 kPa or 1.4 kgf/ 
cm
2
 (takes more than 4 seconds to fill a cup of 7 oz 
or 198 cc capacity):
• Check to see if the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if 
necessary.
• Allow the storage tank on the reverse osmosis 
system to refill after heavy usage.
• If the water pressure remains low, call a 
licensed, qualified plumber.
• All installations must be in accordance with local 
plumbing code requirements.
Supplies Needed
• Copper or PEX Tubing, ¼ in. outer diameter, to 
connect the refrigerator to the water supply. Be 
sure both ends of the tubing are cut square. To 
determine how much tubing you need, measure 
the distance from the water valve on the back of 
the refrigerator to the water supply pipe. Then, 
add 8 feet (2.4 m). Be sure there is sufficient 
extra tubing (about 8 feet [2.4 m] coiled into 3 
turns of about 10 in. [25 cm] diameter) to allow 
the refrigerator to move out from the wall after 
installation.
• Power drill.
• ½ in. or adjustable wrench.
• Flat-blade and Phillips-head screwdrivers.
• Two ¼ in. outer diameter compression nuts 
and 2 ferrules (sleeves) to connect the copper 
tubing to the shutoff valve and the refrigerator 
water valve.
• If your existing copper water line has a flared 
fitting at the end, purchase an adapter (available 
at plumbing supply stores) to connect the water 
line to the refrigerator OR cut off the flared 
fitting with a tube cutter and then use a 
compression fitting.
• Shutoff valve to connect to the cold water line. 
The shutoff valve should have a water inlet with 
a minimum inside diameter of 5/32 in. at the 
point of connection to the COLD WATER LINE. 
Saddle-type shutoff valves are included in many 
water supply kits. Before purchasing, make sure 
a saddle-type valve complies with your local 
plumbing codes.
NOTE
• A self-piercing saddle type water valve should 
not be used.
Water Line Installation Instructions
Install the shutoff valve on the nearest frequently 
used drinking water line.
WARNING
• When using any electrical device (such as a 
power drill) during installation, be sure the 
device is battery-powered, double-insulated or 
grounded in a manner that will prevent the 
hazard of electric shock.
Water Pressure
models with water 
filter
20 - 120 psi (138 - 827 kPa)
where reverse 
osmosis water 
filtration system is 
connected to a cold 
water supply
40 - 60 psi minimum to 
reverse osmosis system 
(2.8 kgf/cm
2
 - 4.2 kgf/cm
2
, 
or less than 2 - 3 seconds 
to fill a cup of 7 oz 
capacity)