LG LG Room Air Conditioner OWNER'S MANUAL MODELS: SV1 Chassis Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm). IMPORTANT ? ? Please read this owner's manual and before air conditioner. installing and carefully operating your room thoroughly Please retain this owner's manual for future reference after reading it thoroughly. P/No.
Room Air Conditioner Owner's Manual TABLE OF CONTENTS FOR YOUR RECORDS Safety Precautions.........................3 Write the model and serial numbers here: Model # Prior to Operation ..........................9 Serial # You find them can on a label on the side of each unit. Dealer's Name Introduction ..................................10 Date Purchased Staple your receipt to this page in the event you need purchase or for warranty issues.
Safety Precautions Safety To Precautions prevent the injury of the user or other people and property damage, the following instructions must be followed. Incorrect by operation due to ignoring following indications. the The meanings of the instruction will cause harm or damage.
Precautions Safety Be cautious when For unpacking and installing the product. contact the dealer Sharp edges could cause injury. Be especially careful of the case edges and the fins on the ? condenser and Be sure ? There is risk of fire, electric shock, explosion, or injury. the installation product defective installation stand. ? It may cause damage injury, accident, product. or to the Do not let the air conditioner area run age.
Safety ? Use a this appliance. dedicated outlet for There is risk of fire or electrical Grasp the plug ? shock. to Do not remove other not touch it with wet hands. power cable. electrical or ? shock. Do not allow water to into electric There is risk of fire and electric shock. Do not store run Do not or use flammable gas or combustibles near the air parts. place a heater or appliances near the the cord from the outlet.
Safety Do not open the inlet grill of product during operation. (Do not touch the When the the (flooded electrostatic Service Center. is ? Precautions so contact filter, if the unit product is soaked submerged), Ventilate the an product from operating time to time when or Authorized it together with a stove, etc. equipped.) There is risk of electric shock, physical injury, product ? There is risk of fire or eletric ? shock. or There is risk of fire or electrical shock.
Safety Do not install the where the noise Use two product or hot air lift and from the outdoor unit could or more Do not install the people to transport the air It may cause a problem for your product exposed to (salt spray) where it will be conditioner. sea damage the neighborhoods. ? Precautions wind directly. ? Avoid personal injury. ? It may cause corrosion on the product. Corrosion, particularly neighbors.
Precautions Safety Always insert the filter securely. Clean the filter every two weeks or often if necessary. Do not insert hands objects through more or dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. Use a firm stool maintaining or ? ladder when other Do not drink the water drained from the unit. outlet while the air conditioner is A ? or the air inlet There parts are sharp that could plugged and in.
Prior to Prior to for Preparing 1. Contact 2. 3. Use an Operation Operation installation in the power Plug Operation specialist plug properly. for installation. dedicated circuit. a 4. Do not use an extension cord. 5. Do not 6. If the start/stop operation by plugging/unplugging the power cord. cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. a long time may be hazardous to your health. Do not expose plants to direct airflow for a long time.
Introduction Introduction Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. This NOTICE symbol indicates special notes. Features WARNING: This regulations. appliance should be installed in accordance with national wiring guide acts as a guide to help to explain product features.
Electrical Electrical Safety WARNING: This To minimize the risk of electric Safety appliance shock, you must must be alway plug properly grounded. into a grounded oulet. Preferred method Ensure proper ground exists before use WARNING: power Do not cut or remove the grounding prong from the plug.
Electrical Safety Temporary Use of an Adapter We strongly discourage the use of an adapter due to potential safety hazards. For temporary use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal.
Operating Instructions Instructions Operating How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new installed batteries making sure that the (+) and (-) of battery are correctly. 3. Reattach the NOTICE cover Use 2 by sliding it back into position. AAA(1.5volt) batteries. use rechargeable batteries. Do not Storage ? and Tips for using the Remote Controller The remote controller may be stored it on a wall.
Operating Instructions Remote Control The controls will look like the Operations following. Controls Signal transmitter 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 2. OPERATION MODE SELECTION BUTTON Used to select the operation mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. 5 5.
Operating Instructions Cooling operation 1 Press the a 2 Start/Stop button. respond with The unit will beep. Open the door of the remote controller. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Auto Cooling Healthy Dehumidification 3 Close the door of the remote controller.
Instructions Operating Auto operation (Cooling model 1 Press the Start/Stop button. respond with The unit will a 2 only) beep. Open the door of the remote controller. To select Auto Operation, press the operation mode selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Auto changeover operation(Heat 1 Press the Start/Stop button. respond with beep. Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling 3 only) The unit will a 2 pump model Instructions Auto changeover Healthy Dehumidification Heating (Heat pump model only) Close the door of the remote controller.
Operating Instructions Healthy dehumidification operation Press the 1 Start/Stop button. respond with The unit will a beep. Open 2 the door of the remote controller. To select Dehumidification Operation, press the Healthy Operation Mode Selection button. Each time the button is pressed, shifted in the direction of the the Auto Cooling operation mode is arrow.
Operating Instructions Heating operation (Heat pump model 1 Press the Start/Stop button. respond with The unit will a 2 only) beep. Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the Auto Cooling 3 arrow. Healthy Dehumidification Heating (Heat pump model only) Close the door of the remote controller.
Operating Instructions Jet cool operation 1 Press the a 2 beep. Press the Jet Cool button to the speed cooling will on 3 Start/Stop button. respond with The unit will operate mode and the unit at super high fan speed mode for 30 minutes. operate cooling To cancel the Jet Cool fan speed button again and the unit mode, press the Jet Cool button, the room temperature setting button will operate at high fan speed on cooling the or mode.
Operating Jet heat Instructions operation (Optional) Press the 1 Start/Stop button. respond with The unit will a beep. Open 2 the door of the remote controller. To select Heating Operation. Auto Cooling Healthy Dehumidification changeover Press the Jet Heat button to 3 speed heating Heating (Heat pump model only) operate the mode and the unit will at super high fan mode for 60 minutes.
Operating Instructions NEO PLASMA purification operation(Optional) 1 Press the Start/Stop button. respond with a The unit will beep. 2 Open the door of the remote controller. Press the PLASMA button. Operation will start when the button is pressed and stop when the button is pressed again. 3 Set the fan speed again controller closed. You with the door of the remote can select the fan speed in four steps-low, medium, high or CHAOS.
Operating 2nd F Instructions operation 1 Press the a 2 Start/Stop button. respond with The unit will beep. Open the door of the remote control and press the 2nd operate functions printed in blue unter Function button to buttons. (Check the indication remote controller.) These buttons can of 2nd function set the timer ON as on the display of the follows: OFF SET CANCEL ON OFF SET AUTO CLEAN 3 For 2nd function the button is more disappears in a pressed again.
Instructions Operating Additional Features mode Sleep 1. Press the 2. The Timer is sleep Mode Auto button to set the time you want the unit to Sleep in one-hour increments programmed stop automatically. by pressing the Sleep Mode Auto button 1 to 7 times. The period in steps of 1 hour, press the Sleep Mode mode is available for 1 to 7 times. To alter the time Button while aiming at air conditioner. Sleep Mode Auto LED lights up.
Operating Instructions Airflow direction control The up/down and right/left airflow using the remote control. can be Press Chaos adjusted by Swing Press the button 30 Press the button to start the unit. Start/Stop button and the louvers will and the louvers will again minutes, the louvers swing. stop. After return to the maximum airflow position automatically. Air circulation mode Circulates the 1. Press the 2. Open air without room Start/Stop the door cooling or heating.
Instructions Operating Forced operation Operation procedures when the remote control can't be used. operation will be started if the power button is pressed. If you want to stop operation, re-press the button. The Power button Cooling Heat pump Model Model Room Temp. ≥ 24°C2 1 °C ≤ Room Temp. Operating mode Cooling Cooling Indoor FAN Speed High High Test operation During the TEST Room Temp.
Maintenance and Service Maintenance and Service Indoor Unit WARNING: Turn the Do not NOTICE use Supply bleach system off before cleaning. To clean, wipe with a soft, dry cloth. abrasives. or power must be disconnected before cleaning the indoor unit. Air filter The air filters behind the front grill should be checked and cleaned every 2 weeks or more often if neccessary. 1. Pull up the front panel.
Maintenance and Service Cleaning ? Recomended 1. Lift the front Filter use period panel, : About 3 months hold it up and pull the Air filter. 2. Remove the Plasma Filters. WARNING: Don't touch the PLASMA Filter within 10 seconds after grille, it may cause opening the inlet electric shock. 3. Put the Plasma Filters into the neutral detergent for 1~2 hours and then raise them. 4. Insert the Plasma Filters after perfectly drying them in shade.
Maintenance and Service Common Problems and Solutions Before calling for service If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer. Air conditioner does not operate 1. Ensure that the air conditioner is 2. Check the fuse or plugged into a proper outlet. circuit breaker. 3. Check whether the voltage is unusually high or low.
Maintenance and Service Troubleshooting The air conditioner may be Problem operating abnormally when: Possible Causes The air conditioner is What To Do ? unplugged. The fuse is blown/circuit breaker is ? sure the air conditioner is plug into the outlet. Check the house fuse/circuit breaker box and tripped. Air Make pushed completely replace the fuse or reset the breaker. conditioner does not start Power failure. ? If power failure occurs, turn the mode control to Off.