Owner's Manual
15INSTALLATION
ENGLISH
a 30" (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an 
unprotected wood or metal cabinet; or 24" (60.9 cm) minimum when bottom of wood or metal cabinet 
is protected by not less than 1/4"(6.4 cm) flame retardant millboard covered with not less than no. 28 
MSG sheet steel, 0.015" (0.381 mm) stainless steel, 0.024" (0.610 mm) aluminum or 0.020" (0.508 mm) 
copper.
b 15" (38.1 cm) minimum between countertop and adjacent cabinet bottom.
NOTE
• Important – Save for the use of the local electrical inspector.
• For installation in Canada, a free-standing range is not to be installed closer than 15/32" (12 mm) from 
any adjacent surface.
Leveling
Leveling the Range
Level the range by adjusting the leveling legs with 
a wrench. Extending the legs slightly may also 
make it easier to insert the rear leg into the anti-tip 
bracket.
Checking Adjustments
1  Place the level diagonally on the oven rack, 
and check each direction for level.
• First check direction a. Then check 
direction 
b.
2  If the level doesn’t show that the rack is level, 
adjust the leveling legs with a wrench.
Connecting Electricity
Electrical Requirements
This appliance must be installed and grounded on 
a branch circuit by a qualified technician in 
accordance with the National Electrical code ANSI/
NFPA NO. 70 - latest edition.
All wiring should conform to Local and NEC codes. 
This range requires a single-phase, 3 wire, A.C 120/
208 V or 120/240 V 60 Hz electrical system. Use 
only a 3-conductor or a 4-conductor UL - listed 
range cord with closed-loop terminals, open-end 
spade lugs with upturned ends or similar 
termination. Do not install the power cord without 
a strain relief.
A range cord rated at 40 amps with 120/240 
minimum volt range is required. If a 50 amp range 
cord is used, it should be marked for use with 13/
8" diameter connection openings. This appliance 
may be connected by means of a conduit or power 
cord. If a conduit is being used, refer to "3-Wire 
Connection: Conduit" or "4-Wire Connection: 
Conduit" sections.
WARNING
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the 
line so that the range can be moved if servicing 
is ever necessary.
• The power supply cord and plug should not be 
modified. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
• Using an extension cord to connect the power is 
prohibited. Connect the power cord and plug 
directly.
• Electrical ground is required on this appliance.
• Make sure that the power cord is not pinched by 
the range or heavy objects. Failure to do so can 
result in serious burns or electrical shock.
us_main.book.book  Page 15  Wednesday, February 3, 2021  9:14 AM