Owner’s Manual
Table Of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- PRODUCT OVERVIEW
- INSTALLATION
- OPERATION
- Control Panel
- Changing Oven Settings
- Clock
- Oven Light
- Timer On/Off
- Wi-Fi
- Settings (Hour Mode, Convection Auto Conversion, Calibrating the Oven Temperature, Preheat Alarm Light, Beeper Volume, Fahrenheit or Celsius, Cooktop On Alert Volume, Wi-Fi On/Off)
- Control Lock
- Start Time (Delayed Timed Cook)
- Cook Time (Timed Cook)
- Minimum & Maximum Default Settings
- Cooktop
- Precautions When Using the Cooktop
- Cooking Areas
- Benefits of Induction Surface Cooking
- Induction Cookware
- Cookware Placement
- Pan Sensing
- Minimum and Maximum Pan Size
- Cookware Compatibility Indicator
- Home Canning
- Using the Cooking Elements
- The Recommended Surface Cooking Setting
- Power Management
- Turning on the Warm Zone
- Oven
- SMART FUNCTIONS
- LG ThinQ Application
- Smart DiagnosisTM Feature
- MAINTENANCE
- TROUBLESHOOTING
- LIMITED WARRANTY
19INSTALLATION
ENGLISH
7 Tighten the 3 screws securely into the
terminal block.
• The center screw now attaches the bent up
ground strap to the block.
a Black
b White
c Red
d Terminal Block
e Ground Strap
f Ground Screw
g Cord/Conduit Connection Plate
h Bend strap up and attach.
3-Wire Connection: Conduit
WARNING
• If screws are not tightened securely, it can result
in electrical spark and severe personal injury or
death.
Conduit Installations
CAUTION
• Do not install the conduit without a strain relief.
1 Remove the cord/conduit connection plate
from the rear of the oven and rotate it.
• The conduit hole (1 1/8") must be used.
2 Prepare the conduit wires as shown below.
a Cord/Conduit connection plate
3 Install the conduit strain relief.
1) Insert the strain relief in the 1 1/8 in. (2.8
cm) conduit hole.
2) Install the conduit through the body of
the strain relief and fasten the strain relief
with its ring.
NOTE
• For conduit installations, purchase a strain relief.
4 Reinstall the cord/conduit connection plate.
Conduit Connections
If the wire in the conduit is copper it must be 8 or
10 AWG wiring.
If the wire in the conduit is aluminum it must be 6
or 8 AWG wiring.
1 Loosen the lower 3 screws from the terminal
block.
2 Insert the bare wire (white/neutral) end
through the center terminal block opening.
Do not remove the ground strap connections.
3 Insert the two side bare wire ends into the
lower left and the lower right terminal block
openings.