Power Wiring (208-230V) and Communications Cable Details
1(L1) 2(L2)
1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2)
1(L1) 2(L2)
S
S S S S
1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2)
Indoor Unit Terminal Block
3 3
Outdoor Unit Terminal Block
L
L
N
N
G
Power Supply
Outdoor unit
Main Switch
Circuit Breaker
Three-wire Power Wiring
(Including Ground)
Fuse
* Same Wiring as Branch Distribution Unit (A)
S
Branch Distribution Unit (B)
3 3
COMMUNICATIONS CABLE
POWER WIRING
L1 L2
1(
L1
)2(
L2
)3(A ) 1(
L1
)2(
L2
)3(B)
Branch Distribution Unit (A)
Indoor Unit Terminal Block Indoor Unit Terminal Block Indoor Unit Terminal Block
Figure 311: Multi F MAX LMU540HV System Power Wiring and Communications Cable.
All field-supplied wiring, components, and materials should follow national, state, and local codes and requirements.
Use only stranded, shielded copper conductor.
Ground wiring is required to prevent accidental electrical shock during current leakage, communication problems from electrical
noise, and motor current leakage. Do not connect the ground line to the pipes.
Install a main shutoff switch or circuit breaker that interrupts all power sources simultaneously.
Wiring cable size must comply with applicable national, state, and local codes.
WIRING CONNECTIONS
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
WIRING CONNECTIONS | 221
Wiring Connections