Brochure
Warranty: 2 years parts; 5 years compressor.
28
DUAL-ZONE
LMU187HV
TRI-ZONE
LMU247HV
QUAD-ZONE
LMU366HV
OUTDOOR UNITS H/P INVERTER
18,000-36,000 BTUs
LMU187HV
Dual-Zone
LMU247HV
Tri-Zone
LMU366HV
Quad-Zone
LMU369HV
Quad-Zone
FEATURES:
QUAD-ZONE
LMU369HV
O
utdoor Model H/P Inverter # LMU187HV LMU247HV LMU366HV LMU369HV
Capacity * BTU/h 18,000 Class 24,000 Class 36,000 Class 34,000 Class
Power Input
(Min.~Rated~Max.) Cooling kW 0.26~1.12~2.37 0.39~1.43~3.09 0.72~3.75~3.92 0.77~2.72~3.92
Heating kW 0.28~1.29~2.48 0.42~2.21~3.10 0.72~3.70~4.10 1.12~3.58~4.10
Running Current Cooling A 1.5~5.2~10.8 2.8~6.6~14.0 3.0~17.4~18.2 3.3~11.8~17.0
Heating A 1.5~6.0~11.3 3.0~10.2~14.1 4.5~17.2~18.8 4.9~15.5~17.8
Power Supply Ø / V / Hz 1/208~230/60 1/208~230/60 1/208~230/60 1/208~230/60
Power Supply Cable(Outdoor) No. x AWG 3 x 12 3 x 12 3 x 12 3 x 12
Transmission Cable
(Outdoor to Indoor unit ) No. x AWG 4 x 14 4 x 14 4 x 14 4 x 14
Dimensions (W x H x D) inch 34 1/4x31 34 1/4x31 34 1/4x31 35 7/16x45
13/16x12 19/32 13/16x12 19/32 13/16x12 19/32 7/8x14 9/16
Net Weight lbs 123.5 130.1 143.3 209.4
Max. # of Connectable
Indoor Units 2 3 4 4
Refrigerant Charge (at 24.6 ft.) oz 67.0 74.1 89.9 123.5
Type R410A R410A R410A R410A
Control EEV EEV EEV EEV
Sound Level (H) Sound Pressure dB(A)+3 51 51 52 57
Piping Connections Liquid inch 1/4 x 2EA 1/4 x 3EA 1/4 x 4EA 1/4 x 4EA
Gas inch 3/8 x 2EA 3/8 x 3EA 3/8 x 4EA 3/8 x 4EA
Piping length spec. Max. total piping ft. 164.0 246.1 246.1 246.1
Max. OD~ID piping ft. 82.0 82.0 82.0 82.0
Piping length
(no add’l refrigerant) ft. 49.2 73.8 123.0 98.4
Max. Elevation Difference Outdoor Unit~Indoor Unit ft. 49.2 49.2 49.2 49.2
Indoor Unit~Indoor Unit ft. 24.6 24.6 24.6 24.6
Operation Range Cooling ˚F 14 ~114.8 14 ~114.8 14 ~114.8 14 ~114.8
(Outdoor) Heating ˚F 5~ 75.2 5~ 75.2 5~ 75.2 5~ 75.2
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 80ºF (26.7ºC ) DB/67ºF (19.4ºC) WB
- Outdoor Temperature 95ºF (35ºC) DB/75ºF (23.9ºC) WB
Heating: - Indoor Temperature 70ºF (21.1ºC) DB/60ºF (15.6ºC) WB
- Outdoor Temperature 47ºF (8.3ºC) DB/43ºF (6.1ºC) WB
Piping Length: - Interconnecting Piping Length 24.6 ft.(7.5m)
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specication may be subject to change without prior notice for purpose
of improvement.
4. For more capacity(*) information, refer to the combination tables.
5. The data mentioned in the above table are only for non-ducted type of indoor unit.
Installation manual
ETL# : 3091879
Defrost /Deicing
Restart delay (3-minutes)
Self diagnosis
Soft start
Auto operation
Auto restart operation
Low ambient operation to 14ºF
(cooling mode)
Gold Fin™ Anti-Corrosion
Exterior Unit Includes:
Exterior unit
charging 2, 3 or 4 indoor coils
(Please see chart below for
actual length amount included)