Combination of Room Capacity Total Capacity Input(W) Current(A) EER SEER
Indoor Unit (kBTU/h Class) Min Middle Max
INDOOR UNIT UNIT-A UNIT-B UNIT-C UNIT-D Total UNIT-A UNIT-B UNIT-C UNIT-D BTU/h kW BTU/h kW BTU/h kW Min Middle Max Min Middle Max
(BTU/h) (BTU/h) (BTU/h) (BTU/h)
2 INDOOR UNITS 9 9 - - 18 8,500 8,500 - - 10,798 3.16 17,000 4.98 19,800 5.80 1,002 1,349 2,560 4.6 6.1 11.6 12.6 19.0
9 12 - - 21 7,586 10,114 - - 11,100 3.25 17,700 5.19 23,100 6.77 1,044 1,383 2,830 4.7 6.3 12.9 12.8 19.0
12 12 - - 24 9,600 9,600 - - 11,400 3.34 19,200 5.63 25,500 7.47 1,194 1,469 3,090 5.4 6.7 14.0 13.1 19.0
9 18 - - 27 6,400 12,800 - - 11,400 3.34 19,200 5.63 27,500 8.06 1,284 1,469 3,090 5.8 6.7 14.0 13.1 19.0
12 18 - - 30 7,680 11,520 - - 11,400 3.34 19,200 5.63 27,500 8.06 1,284 1,469 3,090 5.8 6.7 14.0 13.1 19.0
3 INDOOR UNITS 9 9 9 - 27 6,400 6,400 6,400 - 11,700 3.43 19,200 5.63 28,800 8.44 1,200 1,431 3,050 5.5 6.6 13.9 13.4 21.7
9 9 12 - 30 5,760 5,760 5,760 - 11,700 3.43 19,200 5.63 28,800 8.44 1,200 1,431 3,050 5.5 6.6 13.9 13.4 21.7
9 12 12 - 33 5,236 6,982 6,982 - 11,700 3.43 19,200 5.63 28,800 8.44 1,200 1,431 3,050 5.5 6.6 13.9 13.4 21.7
Heating
Combination of Room Capacity Total Capacity Input(W) Current(A) COP HSPF
Indoor Unit (kBTU/h Class) Min Middle Max
INDOOR UNIT UNIT-A UNIT-B UNIT-C UNIT-D Total UNIT-A UNIT-B UNIT-C UNIT-D BTU/h kW BTU/h kW BTU/h kW Min Middle Max Min Middle Max
(BTU/h) (BTU/h) (BTU/h) (BTU/h)
2 INDOOR UNITS 9 9 - - 18 10,120 10,120 - - 12,418 3.64 20,240 5.93 23,700 6.95 1,200 1,951 2,660 5.5 8.9 12.1 3.0 7.7
9 12 - - 21 9,857 13,143 - - 12,765 3.74 23,000 6.74 27,700 8.12 1,260 2,174 3,010 5.7 9.9 13.7 3.1 7.7
12 12 - - 24 13,200 13,200 - - 16,200 4.75 26,400 7.74 29,040 8.51 1,368 2,320 3,100 6.2 10.5 14.1 3.3 8.2
9 18 - - 27 8,800 17,600 - - 16,200 4.75 26,400 7.74 31,500 9.23 1,428 2,320 3,100 6.5 10.5 14.1 3.3 8.2
12 18 - - 30 10,560 15,840 - - 16,200 4.75 26,400 7.74 31,500 9.23 1,428 2,320 3,100 6.5 10.5 14.1 3.3 8.2
3 INDOOR UNITS 9 9 9 - 27 8,800 8,800 8,800 - 16,200 4.75 26,400 7.74 32,000 9.38 1,308 2,207 3,090 5.9 10.2 14.0 3.5 9.4
9 9 12 - 30 7,920 7,920 7,920 - 16,200 4.75 26,400 7.74 32,000 9.38 1,308 2,207 3,090 5.9 10.2 14.0 3.5 9.4
9 12 12 - 33 7,200 9,600 9,600 - 16,200 4.75 26,400 7.74 32,000 9.38 1,308 2,207 3,090 5.9 10.2 14.0 3.5 9.4
Ducted Type Indoor Unit
Cooling
Combination of Room Capacity Total Capacity Input(W) Current(A) EER SEER
Indoor Unit (kBTU/h Class) Min Middle Max
INDOOR UNIT UNIT-A UNIT-B UNIT-C UNIT-D Total UNIT-A UNIT-B UNIT-C UNIT-D BTU/h kW BTU/h kW BTU/h kW Min Middle Max Min Middle Max
(BTU/h) (BTU/h) (BTU/h) (BTU/h)
2 INDOOR UNITS 9 9 - - 18 8,300 8,300 - - 10,798 3.16 16,600 4.87 19,800 5.80 1,042 1,495 2,560 4.7 6.8 11.6 11.1 14.4
9 12 - - 21 7,286 9,714 - - 12,000 3.52 17,000 4.98 23,100 6.77 1,084 1,504 2,830 4.9 6.8 12.9 11.3 14.4
12 12 - - 24 9,000 9,000 - - 12,300 3.60 18,000 5.28 25,500 7.47 1,234 1,565 3,090 5.6 7.1 14.0 11.5 14.4
9 18 - - 27 6,000 12,000 - - 12,300 3.60 18,000 5.28 27,500 8.06 1,324 1,565 3,090 6.0 7.1 14.0 11.5 14.4
12 18 - - 30 7,200 10,800 - - 12,300 3.60 18,000 5.28 27,500 8.06 1,324 1,565 3,090 6.0 7.1 14.0 11.5 14.4
3 INDOOR UNITS 9 9 9 - 27 6,000 6,000 6,000 - 12,300 3.60 18,000 5.28 28,800 8.44 1,260 1,525 3,050 5.7 6.9 13.9 11.8 16.4
9 9 12 - 30 5,000 5,400 5,400 - 12,300 3.60 18,000 5.28 28,800 8.44 1,260 1,525 3,050 5.7 6.9 13.9 11.8 16.4
9 12 12 - 33 4,909 6,545 6,545 - 12,300 3.60 18,000 5.28 28,800 8.44 1,260 1,525 3,050 5.7 6.9 13.9 11.8 16.4
FLEx MULTI-SPLIT COMBINATION OF INDOOR UNIT
LMU247HV
Non Ducted Type Indoor Unit