Submittal
MultiSITE™ CRC1 - PREMTBVC0
MultiSITE CRC1+ - PREMTBVC1
Dry Contact for Third Party
Thermostat - PDRYCB300
Dry Contact (one [1] contact, 24 VAC
external power) - PDRYCB100
Dry Contact for (two [2] setpoints) -
PDRYCB400
Job Name/Locaon:
Date:
PO No.:
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)
For: File Resubmit
Approval Other
Tag #:
For a complete list of available accessories, contact your LG representave.
For connual product development, LG reserves the right to change specicaons without noce.
© LG Electronics U.S.A., Inc., Englewood Clis, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
1. Acceptable operang voltage: 98V-132V.
2. Piping lengths are equivalent.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied
and must be a minimum of four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be
grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
5. See Engineering Manual for sensible and latent capacies.
6. Power wiring cable size must comply with the applicable local and naonal code.
7. The indoor unit comes with a dry helium charge.
8. This data is rated 0 . above sea level, with 24.6 . of refrigerant line and a 0 . level dierence between
outdoor and indoor units.
9. Must follow installaon instrucons in the applicable LG installaon manual.
Notes:
Performance:
Cooling:
Cooling Capacity
(Min~Rated~Max) (Btu/h)
SEER
EER
Heang:
Cooling Nominal Test Condions:
Indoor: 80°F DB / 67°F WB
Outdoor: 95°F DB / 75°F WB
Heang Nominal Test Condions:
Indoor: 70°F DB / 60°F WB
Outdoor: 47°F DB / 43°F WB
Heang Capacity
(Min~Rated~Max) (Btu/h)
Max. Heang @ Indoor 70°F DB
Outdoor 19°F DB / 17°F WB
HSPF
SEER - Seasonal Energy Eciency Rao EER - Energy Eciency Rao
HSPF - Heang Seasonal Performance Factor
Electrical:
Power Supply (V¹/Hz/Ø) 115/60/1
Outdoor Unit:
MOP (A)
MCA (A)
Cooling Rated Amps (A)
Heang Rated Amps (A)
Compressor (A)
Fan Motor (A)
25
15
11.4
11.4
11.0
0.4
MOP - Maximum Overcurrent Protecon MCA - Minimum Circuit Ampacity
Total Power Input:
Cooling Power Input (kW)
Heang Power Input (kW)
Piping:
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Addional Refrigerant (oz./.)
Min. / Max. Pipe Length (.)²
Piping Length (no add’l refrig., .)
Max. Elevaon (.)
�1/4 Flare
�3/8 Flare
0.22
9.8 / 49.2
24.6
23
Controls Features:
• 24-Hour on/o mer
• Two-way (Up / Down) Auto Swing
• Auto Changeover
• Auto Restart
• Jet Cool / Jet Heat
• Condensate Sensor Connecon
• Energy Saving
• Inverter (Variable Speed Compressor)
• Self-cleaning Indoor Coil
• Sleep Mode
• Ultra-quiet Operaon
Cooling (°F DB)
Heang (°F WB)
14 ~ 118
14 ~ 65
Operang Range:
Outdoor Unit:
Indoor Unit:
Cooling (°F WB)
Heang (°F DB)
53 ~ 75
60 ~ 86
System Data:
Refrigerant Type
Refrigerant Control
Refrigerant Charge (lbs.)
ODU Sound Pressure
(Cooling / Heang) (±1 dB[A])³
IDU Sound Pressure
Cooling (H/M/L/Sleep) (±1 dB[A])³
Heang (H/M/L) (±1 dB[A])³
ODU Net / Shipping Weight (lbs.)
IDU Net / Shipping Weight (lbs.)
Heat Exchanger Coang
R410A
EEV
1.875
50 / 50
42 / 36 / 28 / 21
42 / 36 / 28
58.4 / 60
19.2 / 22
GoldFin™
Fan:
ODU Type
IDU Type
Fan Speeds (Fan/Cool/Heat)
Quanty (ODU + IDU)
Motor/Drive
ODU Max. Air Flow Rate (CFM)
IDU Air Flow
Cooling, Max/H/M/L (CFM)
Heang, Max/H/M/L (CFM)
Dehumidicaon (pts./hr.)
Propeller
Cross Flow
6 / 6 / 6
1 + 1
Brushless Digitally Controlled/Direct
953
459 / 353 / 264 / 148
459 / 353 / 254 / 198
Page 1 of 3
Included Accessories:
Oponal Accessories:
• Wireless Remote Controller — AKB74955602
2.75
9,640 (80%)
10.51
1.142
LS120HXV2
SB_SZ_Mega115V_WallMount_LS120HXV2_2019_08_26_113003
9.5
19.00
3,070 ~ 12,000 ~ 13,780
Outdoor Unit (ODU) - LSU120HXV2, Indoor Unit (IDU) - LSN120HXV2
3,070 ~ 12,000 ~ 13,780
1
Single Zone Mega 115V Wall Mount