Brochure
36 37
DUCTLESS
CEILING CASSETTE
AIR CONDITIONING
SYSTEMS
High-Capacity Split Systems
The Ceiling Cassette models are ideal for light
commercial applications and work well in
large, open spaces. The ceiling cassette is a
useful alternative when floor space is limited.
The outdoor unit for both models operate on
high-voltage (230/208) power.
Single Zone Split Systems
Ceiling Cassette
Ductless Split
Ceiling Cassette Indoor Units
White Finish
42 ,000 BTUs24,000 BTUs
PQRCVSL0QW
PQRCVSL0
PQRCVSL0
PQRCVSL0QW
A
B
25' maximum
8' minimum
16.4' maximum
A
B
OIL TRAP
INDOOR UNIT
INDOOR
UNIT
INDOOR
UNIT
COVER
OUTDOOR UNIT
OUTDOOR
UNIT
OUTDOOR
UNIT
INSTALLATION PLATE
INDOOR UNIT TUBING FLARE NUT PIPING
INDOOR UNIT
DRAIN HOSE
HOSE CLAMP
DRAIN PIPE
TYPE ”A“ SCREW
†
Each system is pre-charged with enough refrigerant to charge 25 ft. of
line and the interior unit.
Except for inverter model, Systems having the outdoor unit mounted
above the indoor unit (e.g. basement installations) have the following
additional requirement: For systems with elevation of 25 ft. (see chart
above and figure A), refrigerant lines must be oil trapped between 8 ft.
and 16.4 ft. of elevation. For systems with elevation of greater than 25
ft. (see chart above), refrigerant lines must be oil trapped at least every
16.4 ft. of elevation.
Figure A.
Example: 25 ft. maximum elevation.
(Oil traps excluded from inverter system.)
DUCTLESS STANDARD SINGLE
ZONE • INVERTER
ELECTRICAL & REFRIGERATION •
QUICK REFERENCE
*Minimum Circuit Ampacity **Maximum Overcurrent Protection
***For LS186HE
All equipment single phase.
NOTE: Please see local electrical codes for
proper wire specifications.
Electrical Specications
Zone Type
System
Model
BTUs
Voltage
Rated
Amps
MCA* MOP**
Indoor Outdoor
Standard
Single-Zone
H/P LS093HE 9,800 36V DC 115 10.5/10.5 15 20
H/P LS122HE 11,500 36V DC 115 10.5/10.5 15 20
H/P LS186HE 17,800 36V DC 230/208 10.4/10.4 15 20
Standard
Single-Zone
Inverter
H/P LS307HV 30,000 230/208 230/208 17.8/17.8 30 35
H/P LS360HV 33,100 230/208 230/208 17.8/17.8 30 35
Refrigerant Line & Formula Specications
†
Zone Type
System
Model
BTUs
Pipe Size
Additional
Refrigerant
Max. length
each pipe
Max.
elevation
Liquid Suction
Standard
Single-Zone
H/P LS093HE 9,800 1/4” 1/2” 0.22 oz./ft. 49’ 25’
H/P LS122HE 11,500 1/4” 1/2” 0.22 oz./ft. 49’ 25’
H/P LS186HE 17,800 1/4” 1/2” 0.22 oz./ft. 66’ 49’
Standard
Single-Zone
Inverter
H/P LS307HV 30,000 3/8” 5/8” 0.38 oz./ft. 98’ 49’
H/P LS360HV 33,100 3/8” 5/8” 0.38 oz./ft. 98’ 49’
Wire Size
Minimum wiring requirements suggested by manufacturer.
Minimum AWG 14-3
12-3***
Indoor/Outdoor Connecting Cable Minimum AWG 18-4