Installation Guide

17
INSTALLATION
ENGLISH
Connecting the Range to Gas
Shut off the range gas supply valve before removing 
the old range and leave it off until the new hook-up 
has been completed.
Because hard piping restricts movement of the range, 
the use of a CSA International-certified flexible metal 
appliance connector should be used unless local 
codes require a hard-piped connection.
A manual valve shall be installed in an accessible 
location in the gas piping external to the appliance 
for the purpose of turning on or shutting off gas to the 
appliance.
Never reuse an old connector when installing a new 
range.
To protect against gas leaks, use a qualified pipe joint 
sealant on all external threads.
1
Install a male 
1
/
2
" or 
3
/
4
" flare union adapter to the 
NPT internal thread of the manual shut-off valve, 
taking care to back-up the shut-off valve to keep 
it from turning.
2
Install a male 
1
/
2
" flare union adapter to the 
1
/
2
" 
NPT internal thread at the inlet of the pressure 
regulator. Use a backup wrench on the pressure 
regulator fitting to prevent damage.
Check that the gas pressure regulator valve is in the 
open position. 
Lever’s open 
position
Lever’s closed 
position
NOTE
•
The gas pressure regulator valve is open when 
shipped. If the range does not work properly 
after installation, make sure the regulator valve 
is still open.
3
Connect a flexible metal appliance connector to 
the adapter on the range. Position the range to 
permit connection at the shut-off valve.
4
When all connections have been made, be sure
all range controls are in the OFF position and the
pressure regulator valve is open before turning 
on
the main gas supply valve. Gas leaks may 
occur in
your system and create a hazard. Gas 
leaks may not
be detected by smell alone.
Check all gas connection joints and fittings for 
leaks with a non-corrosive leak detection fluid, 
then wipe off.
Gas suppliers recommend you purchase and 
install a UL approved gas detector. Install 
and use in accordance with the installation 
instructions.
WARNING
•
Do not use a flame to check for gas leaks.
•
Isolate the range from the gas supply system 
by closing its individual shut-off valve during 
any pressure testing of the gas supply system 
at test pressures equal to or less than 
1
/
2
" psig 
(3.5 kPa).
Flexible Connector Hookup
1
/
2
" 
Adapter
1
/
2
" Adapter
1
/
2
" 
Adapter
Pressure 
regulator
Flex connector
(6 ft. max.)
Gas shut-off valve
1
/
2
" or 
3
/
4
" 
Gas pipe
Gas Flow into Range
Installer: Inform the consumer of the location of the gas 
shut-off valve
.
Pressure Regulator Position 
Pressure Regulator