User guide
16
ALARM IN connections
Connect external sensors to the 8-pin haness connec-
tor. Each alarm sensor should be connected with G 
(GND). Input specifications are low-active, non-volt-
age contact (ON when active) or open collector (Low 
when active).
Cautions 
Alarm input connection must be connected to only 
one port of two communication ports.
Do not connect one alarm sensor to the several 
camera’s alarm input connector.
Data Port B
Data Port A Adapter
Adapter
Alarm  
sensors (1-4)
Alarm  
sensors (5-8)
•
•
Connection of the data port and adapter 
for alarm input
Data Port A
No Description Color
1 ALARM IN 1 Brown
2 ALARM IN 2 Blue
3 GND Yellow
4 TRX D - Green
5 TRX D + Red
6 GND Black
7 ALARM IN 3 Orange
8 ALARM IN 4 White
No Description Color
1 ALARM IN 1 Black
2 ALARM IN 2 Brown
3 GND Red
4 TRX D - Orange
5 TRX D + Yellow
6 GND Green
7 ALARM IN 3 Blue
8 ALARM IN 4 White
Alarm sensor 2
Alarm sensor 1
Alarm sensor 3