Specification Guide

Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
6 | INTRODUCTION
Ceiling-Concealed Ducted System Engineering Manual
Convergence of Technological Innovation with Flexibility and Style
ARCHITECTURAL APPEAL
Single-Zone Ceiling-Concealed
Ducted Systems
A ceiling-concealed ducted system provides a system designer an
edge to engineer a system with individual control, and design flex-
ibility with advanced controls. Ceiling-concealed ducted systems are
208-230V/60Hz/1PH systems available in nominal capacities of 3/4,
1, 2, and 3 tons, and are best suited for applications with zones that
require heating or cooling, such as residential, and small business
office buildings.
Benefits of Ceiling-Concealed Ducted Systems
Inverter technology
Low static available in 9,000 and 12,000 Btu/h; High static
available in 24,000, and 36,000 Btu/h capacities
All-season use—heat pump models for both cooling and heat-
ing capabilities
Operating ranges for 9,000 and 12,000 Btu/h low static outdoor
units of 0°F to +118°F (DB) for cooling (Cooling range can be
extended from 0°F down to -4°F using the Low Ambient Wind
Baffle Kit [sold separately]); -4°F to +64°F (WB) for heating
Operating ranges for 9,000 and 12,000 Btu/h low static indoor
units of 57°F to 77°F (WB) for cooling; 59°F to 81°F (DB) for
heating
Indoor unit temperature for 9,000 and 12,000 Btu/h of 65°F to
86°F (DB) for cooling; 61°F to 86°F (WB) for heating
Operating ranges for 24,000 and 36,000 Btu/h high static
outdoor units of 5°F to +118°F (DB) for cooling; 0°F to +64°F
(WB) for heating
Operating ranges for 24,000 and 36,000 Btu/h high static
indoor units of 57°F to 77°F (WB) for cooling; 59°F to 81°F
(DB) for heating
Indoor unit temperature setting range for 24,000 and 36,000
Btu/h) of 65°F to 86°F (DB) for cooling; 61°F to 86°F (WB) for
heating
Quiet operation inside and outside
Inverter Technology
Inverter variable-speed compressors are measurably quieter and
consume less energy than those in conventional air conditioners.
The Inverter compressor ramps up or down to match the required
room capacity and maintain the comfort level. When the
selected temperature is reached, the inverter compressor oper-
ates at low speed to maintain that comfort level, thereby using less
energy.
Adaptable and Flexible
Ceiling-concealed ducted systems allow cooling or heating for a
single room without the need for extensive remodeling. Long refrig-
erant piping lengths allow for extra design flexibility in indoor unit
installation. These units may be used for a number of residential or
commercial environments such as:
Older homes
New home construction
Office buildings
Restaurants
Hospitals / Medical facilities
Schools
Nursing homes
Retail establishments
Houses of worship
Figure 1: Ceiling Concealed High Static Ducted System.