Operating Instructions LVC-S60HM LVC-S60HP LVC-S60NM LVC-S60NP Before installing and using the camera, please read these instructions thoroughly and retain them for later reference.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, Warning To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet Refer servicing to qualified personnel only. Wiring methods shall be in accordance with the National Electric Code, ANSI/NFPA 70. DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Contents Features ..................................................................................................................................3 Cautions for Safe Operation ......................................................................................................4 Operating Controls and Their Functions ..............................................................................5-6 Connections .................................................................................................
Cautions for Safe Operation Power Supply They must be operated with a AC 24V class 2 power supply and DC12V alternatively. * Notes: Be careful of AC frequency when the camera is operated with Line lock mode. AC24V(60Hz):S60HM/S60NM AC24V(50Hz):S60HP/S60NP Handling of the unit Be careful not to spill water or other liquids on the unit. Be cautions not to get combustible or metallic material inside the body.
OPERATING CONTROLS AND THEIR FUNCTIONS DC 12V VIDEO OUT AES VIDEO DC IRIS POWER PHASE AC 24V~ 1 7 1 2 3 4 5 6 4 3 2 9 5 6 8 CLASS 2 ONLY 10 12 11 Pin assignment of auto iris lens connector 3 4 1 2 Tripod adapter CCD cover Dip switches Line phase adjustment volume Lens selection switch DC iris level adjustment volume Pin No.
OPERATING CONTROLS AND THEIR FUNCTIONS ➀ ② The Adjustment method of Line Lock Phase When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, refer to the below. -The vertical sync phase can be manually adjusted within the range approximately from -90o to +90o. - Switch the display on the monitor from camera1 to camera2. Adjust the PHASE volume on camera2 until the vertical roll of the image stops.
CONNECTIONS DC 12V DC12V Power Connection LVC-S60 (DC12V/AC24V Compatible) 1. DC 12V Power Supply Remove the insulation on the power cable as illustrated and connect the power cord to the AC/DC compatible terminals on rear panel of the camera. Note : You don't need to be cautious of the polarity of positive and negative. (Auto polarity sensing) 2.
Lens Mounting Remove the CCD cover. Then attach the CS mount lens to the camera. Please refer to the drawing on the left. C Mount Lens: You have to use the Adapter Ring Mount (not supplied). CAUTION Be cautious not to use Auto Iris Lens with over 30mA DC iris level is preset in the factory. Only if necessary, adjust the DC iris level to achieve the proper picture with AGC off.
BACK FOCUS ADJUSTMENT If back focus has to be adjusted after mounting the lens, 1. Loosen the back focus lock screw(1) on top of the camera with a (+) screwdriver 2. Turn the back focus adjustment screw(2) on top of the camera with hands until the desired focus is reached. 3. Tighten the back focus lock screw(1). Note : When tighten screw, do not inflict unreasonable force. It may damage to the unit.
INSTALLATION OF CAMERA This camera is mounted with tripod which makes it possible to install from both of the bottom and the top of the unit as illustrated.
Specifications Model Signal System Total/Effective Pixels Pick-Up Device Lens Iris Control Signal Process Scanning System Sync. System Scanning Frequency Resolution S/N Ratio Standard Illuminance Sensitivity (1/3 Output) Video Output Signal Back Light Gain Control Flickerless White Balance Exposure Power Source Power Consumption Operation Temp. Storage Temp.