Owner's Manual
9
INSTALLATION
EN
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. TEST and RESET buttons are provided
on the plug case. The device should be tested on
a periodic basis by first pressing the
TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
for 240 V
RESET
TEST
Use Wall ReceptacleModel
LW1816ER
LW1821ERSM
Power Supply
WARNING
● This appliance should be installed in
accordance with the National Electrical
Code.
● Use of extension cords could cause serious
injury or death.
- Do not use an extension cord with this
window air conditioner.
- Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
● Never push the TEST button during
operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this
plug. If this device trips, the cause should
be corrected before further use.
CAUTION
● The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamper-
resistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
Standard 240 V, 3-wire
grounding receptacle
rated 15 A / 240 VAC /
60 Hz
Use 15 A, time
delay fuse or
15 A, circuit
breaker.
Use Wall ReceptacleModel
LW1516ER
LW1521ERSM
Power Supply
Standard 120 V, 3-wire
grounding receptacle
rated 15 A / 120 VAC /
60 Hz
Use 15 A, time
delay fuse or
15 A, circuit
breaker.
for 120 V
RESET
TEST
RESET
TEST
Use Wall ReceptacleModel
LW2516ER
LW2521ERSM
Power Supply
Standard 240 V, 3-wire
grounding receptacle
rated 20 A / 240 VAC /
60 Hz
Use 20 A, time
delay fuse or
20 A, circuit
breaker.