Please read this manual carefully before operating the unit.
Room Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS Safety precautions Safety Precautions ..................................................3 Write the model and serial numbers here: Model # Operating instructions Caution while operating Air Conditioner ..................4 About the Controls on the Air Conditioner ...............8 Care and Maintenance ..........................................13 Serial # You can find them on a label on the side of each unit.
Safety Precautions To prevent injury to the user or other people and property damage , the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. The serIousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury . CAUTION This symbol indicates the possibility of injur y or damage to proper ties only. n Meanings of symbols used in this manual are as shown below .
CAUTION WHILE OPERA TING AC n Operation Do not place heavy object on the power cord and take care so that the cord should not be pressed. Do not share the outlet with other appliances. • There is danger of fire or electr ic shock. • It will cause electr ic shock or fire due to heat generation. Do not place the power cord near a heater. • It may cause fire and electr ic shock. Do not allow water to run into electric parts. • It will cause failure of machine or electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug. • It will cause electr ic shock or fire due to heat generation. Hold the plug by the head when taking it out. • It may cause electric shock and damage. Do not damage or use an unspecified power cord. • It will cause electr ic shock or fire. When gas leaks, open the window for ventilation before operating the unit. • Otherwise, it may cause explosion, and a fire. CAUTION -5- Do not operate with wet hands or in damp environment.
n Operation Do not put a pet or house plant where it will be exposed to direct air flow. • It may cause injury. Do not step on the indoor/outdoor unit and do not put anything on it. • It may cause an injur y through dropping of the unit or f alling down. Be cautious not to touch the sharp edges when installing. • It may cause injury. Do not block the inlet or outlet of air flow. Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. • It may cause product failure.
Before Operation Preparing for Operation 1. 2. 3. 4. 5. 6. Contact an installation specialist for installation. Plug in the power plug properly. Use a dedicated circuit. Do not use an extension cord. Do not start/stop operation by plugging/unplugging the power cord. If the cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
About the Controls on the air conditioner TEMPERATURE Operation Thermostat OPERATION AUTO SWING Auto Swing 5 Off Off 4 On Med Fan High Cool Low Fan Med Cool Off Coolest Wait for 3 minutes before restart 8 1 Cool Low Cool On Low Fan 9 Coolest Wait for 3 minutes before restart Cooling Model (Fig.1) High Cool Med Fan 7 3 2 Cool Off 6 Med Cool Low Cool Cooling Model (Fig.2) Cooling Model (Fig.3) OFF: Stop all operation. FAN: Circulates filtered air.
Your Panel may look like any of below mentioned panels.
Controls Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner. 1 POWER // (ON/OFF) BUTTON Operation starts, when this button is pressed and stops when you press the button again. 2 OPERATION MODE SELECTION BUTTON Select (A)Cool (B)Energy Saver (C)Fan & (D)Dehumidification (dry) with this button.
REMOTE CONTROLLER Type 1 Type 2 POWER (e) Turbo HIGH COOL Saver Silent High Fan Low Fan Comfort 1 27°C LOW COOL 24°C HIGH FAN 21°C TEMP 3 Cool Auto Swing Super Cool Mode Temp 2 3 1 4 LOW FAN 18°C Auto Swing 4 FAN SPEED 5 Mode Temp ON/OFF MODE 2 2 3 1 AUTO SWING 4 Controls Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air con
Additional controls and important information. Vent Control The vent control is located above the control knobs. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside. CLOSE VENT OPEN To open the vent, pull the lever toward you. To close it, push it in. Air Direction The direction of air can be controlled horizontally or vertically by using the horizontal louver or vertical louver.
Care and Maintenance Grille and Case To clean, use water and a mild detergent. Do not use bleach or abrasives. Turn the air conditioner off and remove the plug from the wall outlet before cleaning. Air Filter Ensure the power is of f before open the front Grill. The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. The grille is designed to clean the filter downward.
Installation Instructions Select the Best Location A To prevent vibration and noise, make sure the unit is installed securely and firmly. B C Install the unit where the sunlight does not shine directly on the unit. D There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
Installation Instructions Install the Air Conditioner in the Case A E Slide the air conditioner into the case. Reinstall the screws removed earlier on each side of the case. Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place. Deo-filter* Screw Power Cord Screw CAUTION: The power cord must be connected to an independent circuit. The green wire must be grounded.
Before you call for service... Normal Operation You may hear the thermostat click when the compressor cycles on and off. Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit. The fan may run even when the compressor does not. Hissing Noise- Sound of liquid refrigerant passing through the system. Abnormal Operation Problem What To Do Possible Causes The air conditioner is unplugged.
10 Easy Steps to find out your AC tonnage Dear Customer, Please follow Below mentioned 10 easy steps to find out the AC tonnage required for your room. Step 1 Parameter Room Volume (Cubic feet) upto 1000 1001 ~ 2000 2001 ~ 3000 3001 ~ 4000 Score Step 2 3 4 5 6 Window Area exposed to sun (in sq. ft.) - (West facing) 2 upto 10 11 ~ 20 21 ~ 30 1 2 3 7 0 1 2 3 8 Window Area exposed to sun (in sq. ft.) - (other directions) 3 4 5 upto 10 11 ~ 20 21 ~ 35 36 ~ 50 Wall Area exposed to sun (in sq. ft.
BRANCH BRANCH OFFICE ADDRESS Ahmedabad LGEIL, 233-234, Platinum Plaza, Judges Bunglow Road, Bodakdev Road, Ahmedabad - 51, Tel : 079 - 40040012-17 Asansol LGEIL, Block-E, Ist Floor, P C Chattarjee Market,Rambandhu Tala, GT Road (E) Asansol-713303, Tel : 0341 -3292009,3292010,3092009,3092010 Aurangabad LGEIL, 302 CIDCO No 3, Opp Hotel Ramgiri, Jalna Road, Aurangabad - 431003, Tel : 0240 - 5625705,2474055,3295436,3295437,3295438,3095438 Bangalore LGEIL, 93,TKN Mansion, Ground Flr, KH Road, Banglore-5
LG Electronics India Pvt. Ltd. Registered Office: Plot No. 51, Surajpur Kasna Road, Greater Noida - 201 306 (U.P.) INDIA Tel: 0120-2560900 Fax: 0120-2560957 MTNL / BSNL (Toll Free) Prefix STD Code P/No.: MFL37725125 The picture shown on Front page is representative model. LG Electronics reserves its right to change, modify or alter design without any prior notice. Global No.1 source : Japan Air Conditioning, Heating and Refrigeration News (JARN), December 2005.