Installation guide
6 Multi-Type Air Conditioner
Installation of Indoo
Installation of Indoor
1. Indoor unit
• There should not be any heat source or
steam near the unit.
• There should not be any obstacles to
prevent the air circulation.
• A place where air circulation in the room
will be good.
• A place where drainage can be easily
obtained.
• A place where noise prevention is taken
into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows
from the wall, ceiling, or other obstacles.
• The indoor unit must keep the
maintenance space.
Selection of the best location
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Above 250
330 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
More than
30cm
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
20 or more
Above 250
330 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
❈ Please use an annexed sheet or the
corrugated cardboard on the bottom of
packing as installation sheet.
❈ When using the bottom sheet, please use it
after separating the installation sheet from
packing of the product floor by using a knife
etc as a picture below.
Annexed sheet
Or
Packing corrugated
cardboard on the
bottom