Indoor Model Number LMDN096HV LMDN126HV LMDN186HV
Capacity
1
¹ (BTU/hr) 9,000 BTU Class 12,000 BTU Class 18,000 BTU Class
Controller Wired Non-Programmable Wired Non-Programmable Wired Non-Programmable
Controller operating range
Cooling
18 ~ 30°C (64 ~ 86°F) 18 ~ 30°C (64 ~ 86°F) 18 ~ 30°C (64 ~ 86°F)
Heating
16 ~ 30°C (61 ~ 86°F) 16 ~ 30°C (61 ~ 86°F) 16 ~ 30°C (61 ~ 86°F)
WLAN Smart Phone Control No No No
Unit Dimension W x H x D (Inch) 27 9/16 x 7 15/32 x 27 9/16 35 7/16 x 7 15/32 x 27 9/16 35 7/16 x 7 15/32 x 27 9/16
Net Weight Unit (Lbs) 38.6 50.7 50.7
Air Filter Type Included Washable Washable Washable
Power Supply (Ø / V /Hz) 1 / 208~230 / 60 1 / 208~230 / 60 1 / 208~230 / 60
Running Current .25A .25A .25A
Connecting Wire Outdoor To Indoor
2
: (LMU18CHV, LMU24CHV, LMU30CHV,
LMU36CHV, LMU187HV, LMU247HV, LMU369HV)
4 x minimum 16# (ground
included) stranded, rated at
300V minimum
4 x minimum 16# (ground
included) stranded, rated at
300V minimum
4 x minimum 16# (ground
included) stranded, rated at
300V minimum
Connecting Wire Distributor Box To Indoor
2
:
(LMU480HV & LMU540HV + PMBD36xx)
4 x minimum 18# (ground
included) stranded, rated at
300V minimum
4 x minimum 18# (ground
included) stranded, rated at
300V minimum
4 x minimum 18# (ground
included) stranded, rated at
300V minimum
Air Flow Rate (cfm 0.2” ESP) Hi ~ Med ~ Low 318 ~ 247 ~ 194 353 ~ 300 ~ 247 530 ~ 441 ~ 353
Sound Pressure (dBA) 30 ~ 26 ~ 23 31 ~ 28 ~ 27 36 ~ 34 ~ 31
Condensate Connection OD (Inch) 1 1/4 1 1/4 1 1/4
Liquid Line Connection (Inch) 1/4 1/4 1/4
Gas Line Connection (Inch) 3/8 3/8 1/2
Charge Adjustment Over Precharge Length (Oz / Ft) .22 .22 .22
Warranty: 5 years parts
9,000 & 18,000 BTU
Multi F Low-Static Air Handler
LMDN
Optional Accessories:
• PREMTB10U programmable wired controller
• Contact LG Technical Support regarding Dry Contact options for external control at 866-543-8324
1
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
2
All electrical wiring must comply with applicable local, provincial and national codes.