Owner's Manual
143
INSTALLER SETTING
142
INSTALLER SETTING
ENGLISH
Guard timer(air conditioner)
It is a function that sets the minimum running time of outdoor unit cycle mode when switching
from cooling mode to heating mode and vice versa during Auto Operation mode.
Under the condition of cooling/heating switching, it switches between cooling and heating mode
after operation during the time scheduled in the Guard timer.
Fan speed in Cooling thermal off (air conditioner)
Indoor unit fan, in cooling mode, during thermal off condition.
• Select value using [<,>(left/right)] button.
Step Value
0 0 minute
1 15 minutes
2 30 minutes
3 45 minutes
4 60 minutes
Value
Low Fan speed low
Off Fan off
Setting fan speed setting value