PREMTBVC Owners Manual

37
User Interface Guide
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
CONFIGURATION SCREENS
Emergency Heat Settings*
Press the right arrow button once on the first heater screen to display the 2/3 Heat Settings screen. and the Emerg Heat (18)
controls. Enabling the Emerg Heat (18) control will display all controls shown below.
Installer
Disable(0)
2/3 Heat Settings
Heater
Off(0)
Fan
Enable(1)
Emerg Heat (18)
Parameter Parameter Settings
Emerg Heat (18)* Use this function to enable or disable emergency heating.

Default value = Disabled(0)
Heater 
Default value = Disabled(0) - Provides Aux Heat during error.
Only Column 1 is available on Gen. 2 equipment.
Column 2 values are available on Gen. 4 and newer equipment.
Column 1
1– “-10°F / -5°F (1)”
2 – “-5°F / 0°F (2)”
3 – “0°F / 5°F (3)”
Column 2
1– “-10°F / -5°F (1)”
2 – “-5°F / 0°F (2)”
3 – “0°F / 5°F (3)”
4 – “5°F / 10°F (4)”
5 – “10°F / 15°F (5)”
6 – “15°F / 20°F (6)”
7 – “20°F / 25°F (7)”
8 – “25°F / 30°F (8)”
9 – “30°F / 35°F (9)”
10 – “35°F / 40°F (10)”
11 – “40°F / 45°F (11)”
12 – “45°F / 50°F (12)”
13 – “50°F / 55°F (13)”
14 – “55°F / 60°F (14)”
15 – “60°F / 65°F (15)”
Fan 󰀨
Default value = O󰀨(0)
*Note: To enable FC-18, rst enable FC-21 and FC-25, wait 10 seconds then enable FC-18.