,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 1 ENGLISH 中文 OWNER’S MANUAL LG Air Purifier Please read this manual carefully before operating your set and retain it for future reference. Model name : PS-W309 series P/NO : MFL68181325 www.lg.com/cn Copyright © 2015 - 2017 LG Electronics Inc. All Rights Reserved.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 2 SAFETY PRECAUTIONS 2 ENGLISH SAFETY PRECAUTIONS The precautions related with the safety shown below are to prevent unexpected hazard and damage through safe and accurate operation of the product. ! WARNING If not followed, It may cause death or major injury to the user. ! CAUTION If not followed, it may cause injury to the user or property damage. ! This symbol is to alerts you to hazardous practice and operation.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 3 SAFETY PRECAUTIONS 3 • Insert securely the power plug up to the end of its plug so that it will not be shaken. - If connection is unstable, it may cause fire. • Do not arbitrarily change or extend the power line. - It may cause fire and electric shock. • Do not allow water to be infiltrated into the product. - It may cause fire and electric shock. • Do not place rug etc. on the power cord.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 4 4 SAFETY PRECAUTIONS ENGLISH ! CAUTION Installation • When installing near to TV or audio, provide more than 1 m of distance with them. - TV or audio may have malfunction. • When pulling out the power plug, pull out by grabbing the head of the plug. - It may cause injury or electric shock. • In kitchen, do not use the product as ventilation fan or hood for range. - The life will be shortened.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 5 SAFETY PRECAUTIONS 5 ENGLISH • Do not use the power cord as tied. - Heat generation may cause fire. • Start cleaning and mending after pulling out the power plug and when the fan stops rotating. - You may get electric shock or injury. • Do not use it as a ventilator. - The product life may be shortened. • Completely dry the Dual Protection Filter in a shadow until there is no moisture after washing. - Otherwise, It may cause failure.
1,MFL68181325,영영 2017. 8. 31.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 7 HOW TO INSTALL Selecting installation place Main Unit • Place with handy power connections • Place with no obstacle to clog air inlet • Place with horizontal surface and rich air circulation ! WARNING There can be product failure if the air purifier is installed on a moving vehicle such as cars, boats and others.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 8 8 NAME OF EACH PART ENGLISH NAME OF THE PARTS Front side Display Clean Air Indicator Light This is the light indicating the quality of the air in the room. The odor and dust sensor detects the room air quality, and displays for the cleanliness.
1,MFL68181325,영영 2017. 8. 31.
1,MFL68181325, 2017. 8. 31. 3:06 Page 10 10 NAME OF EACH PART ENGLISH Filter system Lower case (HEPA FILTER) Triple Care Filter Top case (DEODORIZING FILTER) Dual Protection Filter Allergy HEPA Filter Filter name Function Dual Protection Filter It removes large dust particles so that it extends the life of Allergy HEPA Filter.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 11 HOW TO USE 11 ENGLISH HOW TO USE Air Cleaning Operation It cleans the indoor with clean and fresh air. 1. Press the button to start air cleaning operation 2. Press the Speed button to select wind speed. • Pressing the Speed button changes wind speed from AUTO → WEAK → MEDIUM → STRONG → TURBO in turn. Auto Low Medium High Turbo • The mode is set in auto when the product starts its initial operation.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 12 12 HOW TO USE ENGLISH Indicator button 1. Press the Indicator button and check the density of PM10 / PM2.5 / PM1.0 • Pressing the button each time checks the density of PM10 → PM2.5 → PM1.0 in turn. Pressing the Indicator button during operation displays the density of PM10 / PM2.5 / PM1.0 at the display for 10 seconds.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 13 HOW TO USE 13 ENGLISH Overall cleanliness color display Odor/dust display Dust particle size Dust density display • Explanation on the display : Since PM1.0 density is Bad(Orange) with 80μm/m3, display dust at the odor/dust display. Since ‘odor’ is displayed at the odor/dust display, odor density is also strong. Since PM1.0 is displayed at the dust particle size display, the density level of PM1.0 is higher than that of PM10 or PM2.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 14 14 HOW TO USE ENGLISH Ionizer operation It generates negative ion and removes various bacteria in the air. 1. Start the air purifier by pressing the 2. Press the button. Ionizer button. • It removes hazardous substances such as bacteria, virus and others in the air. • Whenever it is pressed it changes the operation sequence as Ionizer → reset function → Ionizer.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 15 HOW TO USE 15 ENGLISH Clean Air Indicator Lamp 1. Press the button. 2. Press the Clean air indicator. • You may set and disable the Clean air indicator light. h Clean air indicator light operates as below. Display Clean Air Indicator Lamp h Once Sleep Mode is set, Clean air indicator Lamp is off. h You may set and disable the Clean air indicator Lamp by pressing the Indicator button. Lock function 1. Press the button. 2. Press the onds.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 16 16 HOW TO USE ENGLISH Filter check lamp 1. If the filter check lamp is on, turn off the power of the operating product by pressing button and unplug the power cord from the outlet. 2. Open rear panel of the product and check the filter. If the filters are contaminated, clean or replace. h Please refer to the page 18-20 for the filter cleaning and replacement method. Method1.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 17 HOW TO INSTALL FILTERS 17 Filter installation method before use Use the filter after removing the vinyl cover. 1. Open the rear panel by pulling. 2. Remove the filter from the main unit. 3. Remove the vinyl cover of the filter. 4. Install the filter that vinyl packing is removed. Remove the vinyl. 5. Close the rear panel. 6. Use on a flat surface with no obstacles around the product.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 18 18 HOW TO CLEAN ENGLISH HOW TO CLEAN 1. Turn off power by pressing the button during the operation. Unplug the power cord form the outlet. 2. Pull the filter handle and remove from the main body. • There can be dust accumulation on the filter net. • Before disassembling filter set, move the filters where cleaning is easy. 3. Hold the filter case and pull up the handle of Dual Protection Filter to remove.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 19 HOW TO CLEAN 19 4. Disassemble the upper case and the lower case of the filter. (when replacing filters) Press the push parts on the both of the top case. 5. Disassemble the Triple Care. (when replacing filters) The two of Triple Care filters consist one set. When replacing and reassembling, thick deodorizer filter should be on the upper case. • If both of the deodorizer filters are not installed, it may cause of low performance. 6. Remove Allergy HEPA Filter.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 20 20 HOW TO CLEAN ENGLISH How to clean the filters Filter type Dual Protection filter Allergy HEPA Filter Classification Cleaning cycle How to clean For washing About 1 month cycle cleaning Clean the Dual Protction Filter with a vacuum cleaner or brush, etc., and if the contamination is severe, wash with water.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 21 HOW TO STORE 21 ENGLISH HOW TO STORE How to store If you do not use the product for extended periods of time, keep at dried and shaded place. 1. Start the air purifier by pressing the button. • If it has operated over an hour on a fine day, it can remove the moisture and mildews inside the product. 2. Stop the air purifier by pressing the button and unplug the power cord. Power plug h Shape of the power cord can be different by country. 3.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 22 22 TROUBLESHOOTING BEFORE CALLING FOR SERVICE ENGLISH TROUBLESHOOTING BEFORE CALLING FOR SERVICE If there is a problem with the product, check the following cases first before requesting service to the service center. Symptom Check It does not start at all. • Isn’t the power plug pulled out? • Isn’t the voltage too low? • Insert correctly into the socket. • Check if it is 220 V~. Wind amount is small and there is a noise.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 23 TROUBLESHOOTING BEFORE CALLING FOR SERVICE 23 Check Actions There has been no • Isn’t there foreign substance at • Refer to how to clean the sensor and the sensor? then clean the dust cleaner. change in micro dust concentra• Are you using in an enclosed • In an enclosed area, the cleanliness intion. area? dication levels can stay unchanged. The fine dust concentration value keeps showing high.
1,MFL68181325,영영 2017. 8. 31. 영영 3:06 Page 24 24 PRODUCT SPECIFICATION ENGLISH PRODUCT SPECIFICATION Height Width Depth The external dimension, design and product standard can change to improve the quality of the product. Model name PS-W309 Series Power supply 220 V~ / 50 Hz Product size (width x height x depth) 295 mm x 779 mm x 308 mm *CADR *CCM Purification Energy Efficiency Fine Particle 280 (m3/h) Formaldehyde 60 (m3/h) PM 2.