AC SMART IV BACNET GATEWAY
Features
PBACNA000
• Controls up to 128 indoor units
• Controls up to 16 AHU Control kits
• Provides graphical user interface that allows centralized control
• BTL Listed (B-ASC)
Integrates Multi V and select Mini and Multi Split systems with
third-party building management systems using a large 10.2-inch
touch screen with intuitive GUI (graphical user interface).
Controlling Monitoring Items
On/Off Command
On/Off Status
Operation Mode Setting
Operation Mode Status
Fan Speed Setting
Fan Speed Status
Lock Setting
Lock Status
Air Flow Setting
Air Flow Status
Set Temperature Setting
Set Temperature Status
-
Current Space Temperature Status
-
Error Status
User Mode Setting (for only ERV)
User Mode Status (for only ERV)
-
Accumulator Power Distribution Status
Upper Limit Temp. Setting
Upper Limit Temperature Status
Low Limit Temp. Setting
Low Limit Temperature Status
Mode Lock Setting
Mode Lock Status
AC Operation Mode Setting (ERV DX only)
Air Conditioner Operation Mode Status
(ERV DX only)
AC On/Off Command (ERV DX only)
Air Conditioner On/Off Status
(ERV DX only)
Indoor unit : Max. 128 units (Air conditioner & Ventilation) / Indoor address : 00 ~ FF
BMS system
Internet
Remote Monitoring
Power Monitoring
Lighting Control
CH1~2
MULTI V WATER IV
MULTI V WATER MINI
MULTI V S
MULTI V SPACE II
MULTI V IV
ERV
MULTI F
MULTI F MAX
SINGLE ZONE
1)
AC Smart
NOTE: Available functions/features may differ based on the connected system. Due to our policy of
innovation, some specications may be changed without notication.
1) Assignment of an IP address is required to access central controller through the Internet.
BACnet® is a registered trademark of ASHRAE
System Communication Architecture
Controlling Monitoring Items
On/Off Command On/Off Status
Operation Mode Setting Operation Mode Status
Fan Speed Setting Fan Speed Status
Lock Setting Lock Status
Air Flow Setting Air Flow Status
Temperature setpoint Temperature setpoint status
- Current Space Temperature Status
- Error Status
User Mode Setting User Mode Status
- Accumulator Power Distribution Status
Upper Limit Temp. Setting Upper Limit Temperature Status
Low Limit Temp. Setting Low Limit Temperature Status
Mode Lock Setting Mode Lock Status
AC Operation Mode Setting AC Operation Mode Status
AC On/Off Command AC On/Off Status
Occupied/Unoccupied Occupied/Unoccupied
Dual Temperature Setpoint Setting Dual Temperature Setpoint Status
Requires the appropriate PI-485. Check the product's engineering manual for details.