Owner's Manual

36
ENG
ENGLISH
CUSTOMIZING SETTINGS
Parameter
Value
Unit Notes
Min Typ Max
T1 0.5 - 20 ms
T2 0 - - ms 4
T3 200 - - ms 3
T4 200 - - ms 3
T5 1.0 - - s 5
T6 - - T2 ms 4
T7 0.5 - - s
T8 100 - - ms 6
y
The T3 / T4 is recommended value, the case when failed to meet a minimum specification,
abnormal display would be shown. There is no reliability problem.
Power Sequence
y
TSP500 requires additional transparent display and backlight in order to display image properly.
y
If you do not follow the booting sequence below while launching backlight, the screen may be
displayed abnormally (blinking or vertical stripes).
Power Supply For LCD
V
LCD
Interface Signal (Tx)
User Control Signal
(LVDS_select, BIT_select)
Power for Lamp
T1
0V
10%
90%
10% 10%
90%
T5
T8
30%
0V
T2
Vcm : LVDS Common mode Voltage
T6
100%
T3
T4
Lamp ON
T7
Valid Data
CAUTION