Specification
Table Of Contents
3 of 5
F
E
I
F
I
G
B
A
3/24
WKEX300HBA / WKGX301HBA
DIMENSIONS / CLEARANCES
27''
(700 mm)
1''
(25 mm)
1''
(25 mm)
1''
(25 mm)
74
3
/8''
(1890 mm)
Dimensions / Clearances
To ensure sufficient clearance
for water inlet hoses, drain
hose and airflow, allow
minimum clearances of at
least 1'' (2.5 cm) at the sides
and 4'' (10 cm) behind the
appliance. Be sure to allow for
wall, door, or floor moldings
that may increase the
required clearances.
Exhaust
Choose a location that allows
for proper exhaust installa-
tion. A gas dryer must be
exhausted to the outdoors.
57
3
/8''
(1456 mm)
32
5
/8''
(830 mm)
4''
(100 mm)
6
1
/
16
''
(154 mm)
41
3
/8''
(1050.9 mm)
41
3
/8''
(1050.9 mm)
14
1
/4''
(362 mm)
SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
48 sq. in.
(310 cm
2
)
24 sq. in.
(155 cm
2
)
3'' (76 mm)
4'' (100 mm)
Front Clearance
3'' (76 mm)
Closet Ventilation Requirements
Closets with doors must have both an upper and lower vent to
prevent heat and moisture buildup in the closet. One upper vent
opening with a minimum opening of 48 sq. in. (310 cm
2
) must be
installed no lower than 6 feet above the floor. One lower vent
opening with a minimum opening of 24 sq. in. (155 cm
2
) must be
installed no more than one foot above the floor. Install vent grills in
the door or cut down the door at the top and bottom to form
openings. Louvered doors with equivalent ventilation openings are
also acceptable.
CORRECT VENTING INCORRECT VENTING
ELECTRIC & GAS CONNECTION LOCATIONS (REAR VIEW)
ELECTRIC & GAS CONNECTION LOCATIONS (REAR VIEW)
Power Cord (for Gas Models)
Terminal Block Access Panel
(for Electric Models)
Cold Water Inlet
Exhaust Duct Outlet
Gas connection (for Gas Models)
Hot and Cold Water Inlets
Shipping Bolts
Drain Hose
Power Cord (for Washer)