Installation Guide

29INSTALLATION
ENGLISH
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed transition duct
Too many elbows or exhaust too long
Check for blockages and lint buildup.
Power
Supply
/ High
Voltage
/ Low
Voltage
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Gas
Supply
Gas supply or service turned off. (Gas
Model only.)
Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Duct
Blocka
ge
(80%) /
Duct
Blocka
ge
(90%) /
Duct
Blocka
ge
(95%)
Exhaust system is too long or has too
many turns/restrictions.
Do not use the appliance until the
exhaust system has been cleaned
and/or repaired. Using the
appliance with severely restricted
exhaust is dangerous and could
result in a fire or other property
damage.
Check the outside dryer vent while
the appliance is operating to make
sure there is strong airflow. If the
exhaust system is extremely long,
have it repaired or rerouted.
Door
Open
Door open error.
Do not open the door when doing
installation mode. Restart
Installation mode.
Error
Messa
ges
Possible Cause & Solution
en-us_main.book.book Page 29 Thursday, January 5, 2023 6:55 PM