Ceiling Cassette Single Zone
Electrical & Refrigeration
Quick Reference
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
NOTE: Please see local electrical codes for proper wire specifications.
All equipment single phase.
Electrical Specifications
Type System # BTUs Voltage Rated MCA* MOP**
Indoor Outdoor Amps
Ceiling Cassette
H/P LC246HV 23,000 230/208 230/208 16.1 17.6 25.0
H/P LC426HV 41,000 230/208 230/208 25.3 22.3 40.0
Electrical Specifications
Type System # BTUs
Pipe Size
Liquid Suction
Additional
Refrigent
Max. length
each pipe
Max.
elevation
Ceiling Cassette
H/P LC246HV 23,000 3/8” 5/8” 0.38 oz./ft. 98’ 66’
H/P LC426HV 41,000 3/8” 5/8” 0.43 oz./ft. 164’ 98’
Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
Controls Accessories
Wired Controllers and V-net Integration Board
PI485 V-net control integration accessory
Control integration to LG V-net controls
(AC Smart, ACP, BACnet, LonWorks, etc.)
Applied to LS---HYV, LA---HSV2, LS---HSV2, LS---HV2 & LC---HV indoor units
Applied to LS---HYV, LA180/240HSV2, LS181/240HSV2,
LS360HV2 & LC426HV outdoor units
PQRCVSL0 PQRCVSL0QW PQRCVCL0Q PQRCVCL0QW
PMNFP14A0