CONFIGURATION SCREENS
Heat Settings
Press the Heat Settings button on the Installer screen to display the Heat Settings screen.
Disable(0)
Heat Settings
Ext Aux Heat(25)
Aux Heat Ctrl(21)
HP First(0)
Prim Heat Ctrl(36)
Emergency Heater(18)
Disable(0)
Using the Up and Down arrows select
between Disable, Non-Ducted and
Ducted.
Use this function to enable or
disable auxiliary heat control.
Select between Primary Heat First and
Primary Heat Last.
Conguration Parameters Default Value Parameter Settings
Ext Aux Heat (25)
Default value = Disabled(0)
Choices: 0 = ‘Disable (0)”, 1 = “Non-Duct (0)” , 2 = “Ducted (1)”
Aux Heat Cntrl(21)
Default value = Disabled(0)
This control is used to enable related control on MODE screen
that actually turns the Aux Heat on or off
Choices: 0 = “Disable (0)” , 1 = “Enable (1)”
Primary Heat Cntrl(36)
Default value = HP First(0)
Choices: HP First (0), HP Last (1)
Emergency Heater(18)
Default value = Disabled(0)
Use this function to enable or disable emergency heating.
Choices: 0 = “Disable (0)” , 1 = “Enable (1)”