User Guide
34
MultiSITE CRC 1 Controller
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
CONFIGURATION SCREENS
Emergency Heater Settings
Press the Emergency Heater button on the Heat Settings screen to display the Emergency Heater Settings screen.
Enable(1)
Emergency Heater(18)
Mode
Heater
Off/On
Fan
-10°F/-5°F(1)
Value 3
Value 2
Value 1
Outside A i r
On Temp/Off Temp
Conguration Parameters Default Value Parameter Settings
Value 1 (Mode)
Default value = Disabled(0)
Choices: Disable (0), Enable (1)
Value 2 (Outside Air On/Off Temp)
Default value = Disabled(0)
Choices: Column 1 or Column 2
Only Column 1 is available on Gen. 2 equipment.
Column 2 values are available on Gen. 4 and newer equipment.
Column 1
1– “-10°F / -4°F (1)”
2 – “-6°F / 0°F (2)”
3 – “0°F / 4°F (3)”
Column 2
1– “-10°F / -4°F (1)”
2 – “-6°F / 0°F (2)”
3 – “0°F / 4°F (3)”
4 – “4°F / 10°F (4)”
5 – “10°F / 16°F (5)”
6 – “16°F / 20°F (6)”
7 – “20°F / 24°F (7)”
8 – “24°F / 30°F (8)”
9 – “30°F / 36°F (9)”
10 – “36°F / 40°F (10)”
11 – “40°F / 44°F (11)”
12 – “44°F / 50°F (12)”
13 – “50°F / 56°F (13)”
14 – “56°F / 60°F (14)”
15 – “60°F / 64°F (15)”
Value 3 (Fan)
Default value = Off(0)
Off (0), On (1)