7. Troubleshooting
Problem Cause Correcon
Pump will not run.
Blown fuse or other interrupon of
power; improper voltage.
Check that the unit is securely plugged in. Have
an electrician check all wiring for proper
connecons and adequate voltage and capacity.
Switch is unable to move to the “turn
on” posion due to interference with
the side of basin or other obstrucon
Position the pump or switch so that it has
adequate clearance for free operation.
Insufficient liquid level.
Make sure the liquid level is allowed to rise
enough to activate switch(s).
Defecve switch.
Remove and replace switch.
Pump will not turn
off.
Switch(s) unable to move to the
“turn off” position due to
interference with the side of basin
or other obstacle.
Position the pump or switch so that it has
adequate clearance for free operation.
Defective switch. Remove and replace switch.
Pump runs or
hums, but does not
pump.
Discharge is blocked or restricted.
Check the discharge line for foreign material,
including ice if the discharge line passes
through or into cold areas.
Check valve is stuck closed or installed
backwards.
Remove check valve(s) and examine for freedom
of operaon and proper installaon.
Gate or ball valve is closed. Open gate or ball valve.
Total li is beyond pump's capability.
Try to route piping to a lower level. If not
possible, a larger pump may be required.
Consult the factory.
Pump impeller is jammed or volute
casing is plugged.
*Remove the pump from the basin. Detach
the pump base and clean the area around
the impeller. Reassemble and reinstall.
Pump runs
periodically when
fixtures are not in
use.
Check valve was not installed, is stuck
open or is leaking.
Remove check valve(s) and examine for freedom
of operaon and proper installaon.
Fixtures are leaking.
Repair fixtures as required to eliminate
leakage.
Pump operates
noisily.
Foreign objects in the impeller
cavity.
*Remove the pump from the basin. Detach
the pump base and clean the area around
the impeller. Reassemble and reinstall.
Broken impeller.
Consult the factory for information regarding
replacement of impeller.
Worn bearings.
Return pump to the factory or authorized
repair station for repair.
Piping attachments to building are
too rigid.
Replace a portion of the discharge line with