Submittal Sheet

290_P5 R09/7/2011 ©Copyright 2011 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
3.01 CONSTRUCTION:
Each submersible pump shall be equal to the certified Series 290 SERIES pumps as manufactured by Liberty Pumps, Bergen
NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall
not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a
Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord
entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be
protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless
steel handle.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with 10, 25, 35, or 50 feet of multiconductor power cord. It shall be cord type SJTW, or
SJTOOW capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in
accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the
motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the
ability of water to enter internally through the cord, by means of a damaged or wicking cord.
5.01 MOTORS
Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. At
maximum load the winding temperature shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of
dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for
protecting the motor. The capacitor circuit shall be mounted internally in the pump.
6.01 BEARINGS AND SHAFT
An upper and lower ball bearing shall be required. The ball bearing shall be a single ball / race type bearing. Both bearings shall be
permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and
have a minimum diameter of .311
7.01 SEALS
The pump shall have a unitized carbon / ceramic seal with stainless steel housings and spring. The motor plate / housing interface shall
be sealed with a Buna-N O-ring.
8.01 IMPELLER
The impeller shall be vortex style made of an engineered polymer, with pump out vanes on the back shroud to keep debris away from
the seal area. It shall be threaded to the motor shaft.
9.01 CONTROLS
All pumps can be supplied with a CSA and UL approved VMF type switch, an integrally wired wide angle tilt float switch, or piggy back
type wide angle tilt float switches. The piggy back style switches are equipped with a plug that allows the pump to be operated manually
without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump
control panel.
10.01 PAINT
The exterior of the casting shall be protected with powder coat paint.