Use and Care Manual

©Copyright 2016 Liberty Pumps Inc. All rights reserved. 12
The inner connecting power cord running from the switch box to the
motorized cartridge can be detached by unscrewing the compression nut
located at the motorized cartridge.
4-3-6 Removal of blockage from impeller / impeller replacement:
Once the bottom of the motorized cartridge is accessible, the fasteners retaining the volute can be removed and the
volute separated by pulling it away. The impeller chamber can now be cleaned if required, or the impeller can be replaced.
NOTE: the impeller has a left-handed thread. To remove, use a slotted screwdriver to hold the shaft and turn the impeller
clockwise.
4-3-7 Interconnect hose:
A hose connects the discharge of the motor cartridge (pump) to the discharge flange. To remove this hose, follow the
procedure to remove the discharge flange and motorized cartridge. Both ends of the hose are secured with clamps.
4-3-8 Control Switch:
The control switch cartridge is mounted to the main
cover with fasteners. The control has two power cords,
first is the main power cord that plugs into the house
receptacle and the other powers the motorized
cartridge. The motorized cartridge must be removed to
Impeller has a left handed thread
(counterclockwise to tighten)