Submittal Sheet

FL100_P6 R12/20/2012 ©Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
______ Guide factory mounted rail system with pump suspended by means of thread on quick disconnect which is sealed by
means of nitrile grommets or o-rings. The Discharge piping shall have a check valve. The Discharge piping shall be schedule 80
PVC and furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be
provided with the fiberglass systems.
______ Stainless steel Guide Rail
______ Zinc plated steel Guide Rail
______ "diameter of basin size
______ "height of basin size
______ "distance from top of tank to discharge pipe outlet
______ Fiberglass cover
______ Structural foam polymer cover
______ Steel cover
______ Simplex System with Outdoor panel and alarm
______ Duplex System with Outdoor panel and alarm
______ Separate Outdoor Alarm
______ Remote Outdoor Alarm
14.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture
content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to
ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other
malfunction.
15.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified Facility.
16.01 WARRANTY
Standard limited warranty shall be 3 years.