Install Instructions

©Copyright 2014 Liberty Pumps Inc. All rights reserved
3
MODEL SPECIFICATIONS
Model
HP
Volts
Full Load
Amps
Solids
Handling
Automatic or
Manual
Shut-off
Head
Factory Switch Setting
Turn-on
Turn-off
250*
1/3
115
5.2
1/2”
Manual*
22 ft.
*
*
251
1/3
115
5.2
1/2”
Automatic
22 ft.
11”
4-1/2”
253
1/3
115
5.2
1/2”
Automatic
22 ft.
11”
4-1/2”
257
1/3
115
5.2
1/2”
Automatic
22 ft.
7”
3-1/2”
250HV*
1/3
230
2.6
1/2”
Manual*
22 ft.
*
*
251HV
1/3
230
2.6
1/2”
Automatic
22 ft.
11”
4-1/2”
257HV
1/3
230
2.6
1/2”
Automatic
22 ft.
7”
3-1/2”
280*
1/2
115
8.0
3/4”
Manual*
37 ft.
*
*
281
1/2
115
8.0
3/4”
Automatic
37 ft.
13”
7”
283
1/2
115
8.0
3/4”
Automatic
37 ft.
13”
7”
287
1/2
115
8.0
3/4”
Automatic
37 ft.
9-1/2”
4”
280HV*
1/2
208-230
4.0
3/4”
Manual*
37 ft.
*
*
281HV
1/2
208-230
4.0
3/4”
Automatic
37 ft.
13”
7”
283HV
1/2
208-230
4.0
3/4”
Automatic
37 ft.
13”
7”
287HV
1/2
208-230
4.0
3/4”
Automatic
37 ft.
9-1/2”
4”
290*
3/4
115
10.4
3/4”
Manual*
48 ft.
*
*
291
3/4
115
10.4
3/4”
Automatic
48 ft.
13”
7”
293
3/4
115
10.4
3/4”
Automatic
48 ft.
13”
7”
297
3/4
115
10.4
3/4”
Automatic
48 ft.
9-1/2”
4”
290HV*
3/4
208-230
5.3
3/4”
Manual*
48 ft.
*
*
291HV
3/4
208-230
5.3
3/4”
Automatic
48 ft.
13”
7”
293HV
3/4
208-230
5.3
3/4”
Automatic
48 ft.
13”
7”
297HV
3/4
208-230
5.3
3/4”
Automatic
48 ft.
9-1/2”
4”
FL31M*
1/3
115
10.5
3/4”
Manual*
19 ft.
*
*
FL31A
1/3
115
10.5
3/4”
Automatic
19 ft.
12”
5”
FL32M*
1/3
208-230
5.5
3/4”
Manual*
19 ft.
*
*
FL32A
1/3
208-230
5.5
3/4”
Automatic
19 ft.
12”
5”
FL51M*
1/2
115
12
3/4"
Manual*
55 ft.
*
*
FL51A
1/2
115
12
3/4"
Automatic
55 ft.
13
6”
FL52M*
1/2
208-230
6.5
3/4"
Manual*
55 ft.
*
*
FL52A
1/2
208-230
6.5
3/4"
Automatic
55 ft.
13
6”
FL62M*
6/10
208-230
8.2
3/4"
Manual*
65 ft.
*
*
FL62A
6/10
208-230
8.2
3/4"
Automatic
65 ft.
13
6”
FL63M*
6/10
208-230 3PH
5.6
3/4"
Manual*
65 ft.
*
*
FL64M*
6/10
440-480 3PH
2.8
3/4"
Manual*
65 ft.
*
*
FL72M*
3/4
208-230
10.5
3/4"
Manual*
77 ft.
*
*
FL72A
3/4
208-230
10.5
3/4"
Automatic
77 ft.
13
6”
FL73M*
3/4
208-230 3PH
7.5
3/4"
Manual*
77 ft.
*
*
FL74M*
3/4
440-480 3PH
3.5
3/4"
Manual*
77 ft.
*
*
FL102M*
1
208-230
12
3/4”
Manual*
90 ft.
*
*
FL102A
1
208-230
12
3/4”
Automatic
90 ft.
15”
8”
FL103M*
1
208-230 3PH
9
3/4”
Manual*
90 ft.
*
*
FL104M*
1
440-480 3PH
4.5
3/4”
Manual*
90 ft.
*
*
FL105M*
1
575 3PH
3.3
3/4”
Manual*
90 ft.
*
*
FL152M*
1-1/2
208-230
15
3/4”
Manual*
110 ft.
*
*
FL152A
1-1/2
208-230
15
3/4”
Automatic
110 ft.
15”
8”
FL153M*
1-1/2
208-230 3PH
10.6
3/4”
Manual*
110 ft.
*
*
FL154M*
1-1/2
440-480 3PH
5.3
3/4”
Manual*
110 ft.
*
*
FL155M*
1-1/2
575 3PH
4.9
3/4”
Manual*
110 ft.
*
*
FL202M*
2
208-230
15
3/4”
Manual*
130 ft.
*
*
FL202A
2
208-230
15
3/4”
Automatic
130 ft.
15”
8”
FL203M*
2
208-230 3PH
10.6
3/4”
Manual*
130 ft.
*
*
FL204M*
2
440-480 3PH
5.3
3/4”
Manual*
130 ft.
*
*
FL205M*
2
575 3PH
4.9
3/4”
Manual*
130 ft.
*
*
Note: Manual models (“M” suffix) and 3 phase models, as designated above, require a separate approved pump control device or panel for automatic
operation. Operation of these models will be according to the control selected. Make sure the electrical specifications of the control selected properly
match the electrical specifications of the pump. 3 phase models require overload elements selected or adjusted in accordance with the control or panel
instructions.
WARNING:
Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a
cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other
significant failure.