7.2. Rework on LS6 EVK to evaluate LS9 Module.
If you are using LS6 EVK for LS9 module evolution then
Remove electrolytic capacitor C15, C22, USB connector and Re-
mount and soldier electrolytic capacitor on the back side of the LS6
EVK.
Connect 5v from LS6 EVK to LS9 module USB_VBUS J1-pin 17
7.3. Install USB Composite Drive
To Install USB Composite Drive proceed as below
Download Marvell Windows USB Driver available in Libre Portal
https://librewireless.sharefile.com/share#/view/s465a9d86cfb4fc4b/fi43add6-6929-324d-14ea-
debffef787bf
Connect the power adaptor, press and hold the USB-Boot button, and
simultaneously connect the USB cable and power on the EVK.