Installation Instructions

GB
6
Connecting to the mains
Power supply (AC) and voltage at the operating point must comply
with the details on the type plate, which is located on the inside left
of the appliance, next to the vegetable bins. The socket must be
fused with a 10 A fuse or higher, it must be away from the rear of
the appliance and must be easily accessible.
Connect the appliance with a properly earthed fused plug
and socket only.
Setting up
Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
The oor on which the appliance stands should be horizontal and
level.
The ventilation grilles should not be obstructed. Always ensure
that there is good ventilation and that the outward owing air is
able to escape.
Do not place heat-emitting appliances, e.g. microwave oven,
toaster, etc., on top of the appliance.
Standard EN 378 species that the room in which you install your
appliance must have a volume of 1 m³ per 8 g of R 600a refrigerant
used in the appliance, so as to avoid the formation of inammable
gas/air mixtures in the room where the appliance is located in the
event of a leak in the refrigerant circuit. The quantity of refrigerant
used in your appliance is indicated on the type plate on the inside
of the appliance.
Do not connect the appliance to the supply with other equipment
using an extension cable - risk of overheating.
Appliance dimensions
Appliance venting
The required air flow is directed through the
plinth.
It is important to use the provided ventilation
grille for the ventilation opening.
This opening must not be covered.
Wall
Mounting the anti-tipping device
Caution!
The supplied anti-tipping bracket must be installed in all
cases.
This prevents the appliance from tipping over when the fully loaded
door is opened.
Installation:
1. Mark the centre line of the appliance on the wall.
Align the anti-tipping bracket centre to the centre line on the
wall.
Caution!
Ensure that there are no electric cables or water pipes in
the wall section to which the anti-tipping bracket is to be
secured. These could be damaged during installation.
2. Secure the anti-tipping bracket to the floor using the 5 screws
(6 mm x 60 mm) included in the accessory pack.
Important!
When securing the anti-tipping bracket to a concrete floor,
use suitable plugs!
If the appliance is installed between furniture that has a depth of
more than 620 mm, the appliance will not be in contact with the
anti-tipping bracket.
In this case, it must be installed in a space of 620 mm from the front
face of the appliance to the rear edge of the anti-tipping bracket.
A. 90 mm
B. 2027 mm
C. 910 mm
D. 279 mm
E. 615 mm
F. 2039 mm
G. 1037 mm
H. 1002 mm