Installation Manual
Screws
Grille
Installation Frame
LEVELING THE REFRIGERATOR
2
2
1
3
2
2
3
Figure 11
1. Loosen the lower ventilation grille screws
(Fig. 11, 1).
The height can be adjusted in front by twisting
the leveling wheels (Fig. 11, 2)
.
2. Twist the adjusting bolt (Fig. 11, 3) to set up the
back of the refrigerator.
3. Rotate leveling until firmly in place against the
floor.
4. Align refrigerator with sides of kitchen cabinets
by adjusting leveling wheels and the supports.
5. Install the ventilation grille.
13
MOUNTING THE UPPER VENTILATION GRILLE
Figure 10
IMPORTANT
If you are replacing the factory air vents with
an overlay, DO NOT restrict the air flow. The
air flow must be the same or greater than
the factory air vents of 31 square inches
(200 cm
2
).
Position the ventilation grille at the top of
the installation frame and attach it later with
countersunk screws (4 pieces, provided). Make
sure the grille fits flush laterally with the installation
frame.