Use and Care Manual

Table Of Contents
-
This unit is certified as Sabbath
compliant by the Star-K organization
thus allowing the appliance to be used
during religious holidays. For more infor-
mation please visit Star-K on the web at
www.star-k.org.
1.2 Overview of the appliance and its
equipment
Fig. 1
(1) Rear transport
handles
(11)Interior light
(2) Operating and control
elements
(12)Drain hole
(3) Fan (13)Coldest zone
(4) Container shelf (14)Vegetable drawer
(5) Door rack, moveable (15)IceMaker*
(6) Bottle partition,
adjustable
(16)Freezer compartment
(7) Gallon-capacity rack (17)InfoSystem
(8) Shelf, moveable (18)VarioSpace
(9) Shelf, can be split (19)Rating plate
(10)Bottle shelf (20)Adustable feet, front
transport handles, rear
transport castors
1.3 Range of appliance use
The appliance is only suitable for refrigerating
food in a domestic environment or an environ-
ment that is similar to a domestic one. This
includes, for example, use
-
in staff kitchens, bed and breakfast establish-
ments,
-
by guests in country houses, hotels, motels
and other accommodation facilities,
-
for catering and similar services in wholesale
premises
Only use the appliance in a normal domestic
setting. No other types of use are permissible.
The appliance is not suitable for storing and
refrigerating medicines, blood plasma, labora-
tory preparations or similar substances and
products referred to in CMDCAS and FDA 510
(k). Misuse of the appliance may lead to damage
to or spoiling of the goods stored. In addition the
appliance is not suitable for operating in areas at
risk of explosions.
The appliance is set to operate within specific
ambient temperature limits according to its
climate rating. The climate rating for your appli-
ance is printed on the rating plate.
Note
u
Compliance with the specified ambient
temperatures is required, otherwise the refrig-
eration performance is reduced.
Climate
rating
for ambient temperatures from
SN 50 °F (10 °C) to 90 °F (32 °C)
N 61 °F (16 °C) to 90 °F (32 °C)
ST 61 °F (16 °C) to 101 °F (38 °C)
T 61 °F (16 °C) to 110 °F (43 °C)
1.4 Conformity
The refrigerant circuit has been tested for leaks. The
appliance complies with the relevant safety regulations
and the directives UL250 and CAN/CSA C22.2 No.63-93.
Instructions for testing institutes:
Tests must be carried out in accordance with the appli-
cable standards and guidelines.
The preparation and testing of the appliance must be
carried out taking account of the manufacturer's
loading plans and the instructions in the operating
manual .
The appliance at a glance
* Depending on model and options 3